Led Indicators; Power Connections - Axis 225FD User Manual

Fixed dome network camera
Hide thumbs Also See for 225FD:
Table of Contents

Advertisement

I/O terminal connector schematic diagram
Example schematic diagram of the AXIS 225FD terminal connector - showing possible applications.

LED indicators:

LED Function
Color
1
Network
Green
Amber
Red
Unlit
2
Status
Green
Amber
Red
3
Heater
Green
Red
4
Power
Green
Amber

Power connections

Power can be supplied to the camera by the following methods:
• PoE (Power over Ethernet) via the network cable. This will automatically be detected if available via the network.
Note that PoE only provides power for the camera and the fan (not the heater).
• Connect the supplied indoor power adapter to the power connector block in the camera casing. Note that this
indoor power adapter only provides power for the camera and the fan (not the heater).
• Connect an outdoor power supply to the power connector block in the camera casing. For information on
available outdoor power supplies, please visit the Support pages at http://www.axis.com/techsup/
Power Connector Block
The power connector block supports both AC and DC input power.
The DC supply is 9-24V. Connect the negative pole to the GND pin and the positive pole to the DC+ pin.
AXIS 225FD - Unit Connectors
+3.3V
+3.3V
RS-485/422
Description
Steady for connection to 100 Mbit/s network. Flashes for network activity.
Steady for connection to 10 Mbit/s network. Flashes for network activity.
Flashes rapid red, together with the Status indicator, for hardware error.
No connection.
Shows steady green for normal operation.
Shows steady amber during reset to factory default or when restoring settings.
Slow flash for failed upgrade. Rapid flash, together with the Network indicator, for hardware
error.
Shows steady green if the connected power supply can deliver the correct voltage for the
heater (See Power, on page 42 of Technical Specifications ).
Incorrect voltage for the heater (i.e., the voltage is either too high or too low).
Normal operation.
Flashes green/amber during firmware upgrade.
1
o
Optional
Relay
Switch
2
o
o
o
24V DC
3
o
Switch, etc.
4
o
A
5
o
6
o
B
7 GND
36
o
o
Appliance
o
o o
Mains Power
External Device

Advertisement

Table of Contents
loading

Table of Contents