ERROR DISPLAY
Large division indication
LED indication
Operation
Timer lamp
lamp
(Red)
(Green)
(2 times)
(4 times)
(6 times)
: 0.5s on/off repeated
: 0.1s on/off repeated
2008.08.11
Small division indication

Error contents

thermistor error
control unit error
(indoor unit)
fan motor error
(indoor unit)
LED indication
Operation
Timer lamp
lamp
(Red)
(Green)
(2 times)
(3 times)
(2 times)
(4 times)
(2 times)
(3 times)
6
Error contents
thermistor error
(room temp.)
thermistor error
(heat exchanger)
MANUAL AUTO button error
power source Hz decision error
lock error
rpm error