Midea 11MSFI-A2-1301 Service Manual page 59

Oasis 3d inverter series
Table of Contents

Advertisement

Spec.
Code
Model
MS11MU-09HRFN1-QRD0W
Compressor
Indoor fan motor
Outdoor fan
motor
Code
Model
MS11M-09HRFN1-QRD1W(A)
Compressor
Indoor fan motor
Outdoor fan
motor
Code
Model
MS11M1-24HRDN1-QRC8W
Compressor
Indoor fan
motor
Outdoor fan
motor
Note: The motor marked "★"means DC fan motor with control chip in the PCB while the ones marked "☆" means DC
fan motor with control chip in the fan motor.
2.
Compressor checking
Measure the resistance value of each winding by using the tester.
Position
Blue - Red
Blue - Black
2T0032300815
DA108X1C-20FZ3
WZDK20-38G
(☆)
WZDK35-38G(H)
(★)
2T0032300814
DA108X1C-20FZ3
WZDK20-38G
(☆)
WZDK35-38G(H)
(★)
2T0033000477
DA250S2C-30MT
RPG50C
WZDK50-38G
(☆)
DA108X1C-20FZ3
0.71Ω
(20℃)
2T0032500630
EMS11MU-12HRFN1-QRD0W
DA130M1C-31FZ
WZDK20-38G
(☆)
WZDK35-38G(H)
(★)
2T0032500629
MS11M-12HRFN1-QRD1W(A)
DA130M1C-31FZ
WZDK58-38G
(☆)
WZDK35-38G(H)
(★)
Resistance Value
DA130M1C-31FZ
1.77Ω
(20℃)
59
2T0032800605
MS11MU-18HRFN1-QRC8W
DA150S1C-20FZ
WZDK58-38G
(☆)
WZDK35-38G(H)
(★)
2T0032500647
MS11MU-12HRFN1-QRD0W(B)
DA108X1C-20FZ3
WZDK20-38G
(☆)
WZDK35-38G(H)
(★)
DA150S1C-20FZ
DA250S2C-30MT
0.95Ω
(20℃)
0.55Ω
(20℃)

Hide quick links: