Lexicon 20/20 AD User Manual page 8

Lexicon user guide bit a/d converter 20/20 ad
Hide thumbs Also See for 20/20 AD:
Table of Contents

Advertisement

20/20 AD User Guide
When the compressor is off , the behavior of the level meters is determined by the settings
of the 1dB SCALE, and PK HOLD switches.
When the compressor is on , pressing DISPLAY will cause gain reduction (in dB) to be
displayed on the two right hand meters (2-channel mode) or on all four meters (4-channel
mode).
The following charts show all of the possible states of the level meter and the value in
decibels for each state.
Switches ON
none
4-Channel
1 dB SCALE
Mode
DISPLAY
none
2-Channel
1 dB SCALE
Mode
DISPLAY
DISPLAY
Press to cause gain reduc-
tion to be displayed on the
level meters — In 2-channel
mode, only the right two level
meters are activated; in 4-
channel mode, all four level
meters display compression.
Press again to deactivate.
LINK
In 2-channel mode, links the
left and right compressors ; in
4-channel mode, where 1,2
and 3,4 are already linked,
this control links the two
pairs.
ON
Turns the compressor on
and off.
Meters 1 & 2
Meters 3 & 4
Normal
Normal
1 dB Scale
1 dB Scale
Gain Reduction
Gain Reduction
Normal
(Blank)
Normal
1 dB Scale
Normal
Gain Reduction
DISPLAY
RMT
6
4
LINK
2
0
ON
M
C
VID
GAIN
GAIN
Adjusts the gain of low level
signals (below the compres-
sion threshold) between the
converter and the compres-
sor.
OVL
0
3
6
12
18
24
30
36
42
60
DIGITAL COMP/LIMITER
100
mS
-18
-14
8
-22
-10
10
10
-26
-6
12
0
-36
0
+
• –
P
THRESHOLD
RELEASE
THRESHOLD
Sets the level at which com-
pression starts.
Controls and Connectors
The Level Meters
NORMAL
1dB SCALE
- red -
OVL
OVL
- red -
0
0
- yellow -
-3
-1
- yellow -
-6
-2
- green -
-12
-3
- green -
-18
-4
- green -
-24
-5
- green -
-30
-6
- green -
-36
-7
- green -
-42
-8
- green -
-60
-9
The Compressor
1S
RELEASE
This control allows adjust-
ment of the release time of
the compressor. Release
times from 0mS to
available. The attack time of
the compressor is automati-
cally set as a function of the
signal rise time.
GAIN
REDUCTION
1
2
3
4
5
6
7
8
9
10
11
are
3