8-1-16 TEST Mode
1. The Test mode allows checking the PCB and the function of the product as well as finding out the defective part in case
of an error.
2. The test mode is operated by pressing test button at main PCB controller.
3. While in the test mode, the function control button is not recognized, but the recognition tone sounds.
4. After exiting the test mode, be sure to reset by unplugging and then plugging in the appliance.
5. If an error, such as a sensor failure, is detected while in the test mode, the test mode is cleared and the error code is
displayed.
6. While an error code is displayed, the test mode will not be activated.
Table 1. Function Test
MODE
OPERATION
Push test button one time
at main PCB controller.
TEST1
Push test button again
for TEST MODE 2
TEST2
Push test button again
for TEST MODE 3
TEST3
Push test button for the
4th time and the control is
RESET
Put batch into the
previous setting
FUNCTION
1) Operation of the COMPRESSOR
and FAN(Freezer/Condenser/Icing)
2) Stepping DAMPER OPEN
3) Defrosting HEATER OFF
4) DISPLAY LCD all ON
1) Operation of the COMPRESSOR
and FAN(Freezer/Condenser/Icing)
2) Stepping DAMPER CLOSE
3) Defrosting HEATER OFF
4) DISPLAY LCD shows no. "22"
1) The COMPRESSOR and the
FAN(Freezer/Condenser/Icing) OFF
2) Stepping DAMPER CLOSE
3) Defrosting HEATER ON
4) DISPLAY LCD shows no. "33"
Reset to the previously setting
Before TEST MODE.
- 34 -
REMARKS
Reset if the
Temperature of the
Defrosting Sensor is
46°F(8°C)or more.
The compressor will
Start after a 7-minute
Delay.