Through IP TIP100 User Manual

Remote transceiver interface

Advertisement

Quick Links

THROUGH
IP
REMOTE TRANSCEIVER INTERFACE

User Guide

Advertisement

Table of Contents
loading

Summary of Contents for Through IP TIP100

  • Page 1: User Guide

    THROUGH REMOTE TRANSCEIVER INTERFACE User Guide...
  • Page 2 27 Rostrevor Avenue Rostrevor SA 5073 Australia www.through-ip.com Through IP and TIP100 are trademarks of Through IP Pty. Ltd. registered in Australia and other countries. Other companies and product names mentioned herein may be trademarks of their respective companies. Mention of third party product is for informational purposes only and constitutes neither an endorsement nor a recommendation.
  • Page 3: Table Of Contents

    SYSLOG Messages & Log Level............19 SNMP Monitoring & SNMP Traps............20 Chapter 5 Tips and Troubleshooting..........23 If you can't connect to the web pages of the TIP100......24 If your NGT Handset does not power on..........24 If you can't hear sound..............25 If you have trouble controlling the NGT transceiver......25 TIP100 Status Lights................25...
  • Page 4 Network..................35 Power....................35 Physical...................35 Environmental..................35 Compliance..................36 Index....................37...
  • Page 5: Chapter 1 Welcome

    TIP100 to NGT Handset interface cable. ● TIP100 to NGT Transceiver interface cable. ● What you will need to set up a TIP100 Codan NGT series HF transceiver with NGT handset and a ● speaker. A computer with web browser (e.g. Firefox, Internet ●...
  • Page 6: Tip100 Front Panel

    The status lights blink when the TIP100 interface unit starts up and is establishing a network link. When the TIP100 interface unit is on and has an IP address, the status lights show solid green. For more information on the status lights of the TIP100 interface unit, see page 25.
  • Page 7: Tip100 Rear Panel

    TIP100 Rear Panel TRANSCEIVER Connect the TIP100 interface unit to either the NGT Transceiver or to the NGT Handset using the corresponding interface cable. Connect the TIP100 interface unit to a wired LAN network. Plug the 12V DC power cord from the mains power supply into the TIP100 interface unit.
  • Page 8 Welcome...
  • Page 9: Chapter 2 Getting Started

    Through IP configure the TIP100 Remote Transceiver Interface. To get started you will need to: Have a mains power supply to power the TIP100 interface ● unit. Connect interface cables to your TIP100 interface unit and an ● Ethernet network.
  • Page 10: Setting Up The Tip100

    Plug the power supply into an appropriate electrical outlet and switch on the outlet if required. Step 5: Network startup The TIP100 interface unit will now search for a DHCP server to get an IP address and announce it over the loudspeaker. Getting Started...
  • Page 11: Configuring The Tip100

    If there is no DHCP service available on your network, the TIP100 will try to find an IP address that is suitable for your network, but this can take up to 5 minutes.
  • Page 12: Configuring The Tip100 For The Ngt Transceiver

    Configuring the TIP100 Network Settings The default configuration of the TIP100 interface unit is to connect to the Ethernet network using DHCP and obtain the network setting automatically. These settings can be observed in the top bar of the status screen.
  • Page 13: Configuring The Tip100 For The Ngt Handset

    NGT Transceiver. 7. Click Apply. The TIP100 unit will now restart and will attempt to connect to the transceiver. The progress of this can be observed from the TIP100 status page in your browser (See page 14).
  • Page 14 Getting Started...
  • Page 15: Chapter 3 Using The Tip100

    Read on to learn about using the TIP100 with your Codan NGT series transceiver. Once configured and powered, the TIP100 that is configured for the NGT Handset, initiates the link to the TIP100 that it connected to the transceiver. Handset Operation Once the link is established, the operation of the NGT Handset is essentially as if it is directly connected to the transceiver.
  • Page 16: Network Connections

    UDP and TCP ports enabled for incoming traffic and forward it to the internal IP address of the TIP100 interface unit. In this case it is necessary that the local IP address of the TIP100 unit remains constant. For this purpose, configure the TIP100 manually with an IP address suitable for the internal network.
  • Page 17 (shown as Status LINKING). Once a link is established, the TIP100 interface units will measure the nominal network delay time for the current link. Below that the status of the transceiver power supply, the transceiver itself and the handset is shown.
  • Page 18 TIP100 will use to listen for incoming connections. This port needs to be same port number as is used on the TIP100 in Handset mode. Serial Port (Optional) Only available on TIP100 units with the data mode option enabled.
  • Page 19: Tip100 Configuration Web Page

    TIP100 Configuration Web Page The main configuration screen below is used to configure the TIP100 interface unit between the application mode (“Codan NGT Handset Interface” -or- “Codan NGT Transceiver Interface”), as well as the configuration of the network parameters of the unit.
  • Page 20: Tip100 Handset Configuration Web Page

    TIP100 Handset Configuration Web Page After the TIP100 is configured as either a Handset interface or a transceiver interface, further configuration is needed to configure the network address for the handset to connect to. Using the TIP100...
  • Page 21: Chapter 4 Remote Monitoring

    SNMP Monitoring & Traps • Status Web Page The status web page of the TIP100 allows for monitoring the TIP100 through a standard web browser. In a basic system this may be all that is needed. SYSLOG Messages & Log Level The TIP100 contains a SYSLOG client.
  • Page 22: Snmp Monitoring & Snmp Traps

    SYSLOG server software is widely available for a range of operating systems in both desktop and server variants. Using a SYSLOG server may provide an ability to look at a TIP100 status changes over a period of time. SNMP Monitoring & SNMP Traps The TIP100 can also be monitored using the SNMP v1 protocol.
  • Page 23: Snmp Traps

    Remote Link Mode (1=UDP, 2=TCP) Configured Remote Address SNMP TRAPS For the TIP100 to send SNMP TRAPS, a SNMP Trap address must be configured. This configuration is part of the network configuration under Configuration > Setup. This SNMP trap address can be entered as either an IP address or a domain name.
  • Page 24 Remote Monitoring...
  • Page 25: Chapter 5 Tips And Troubleshooting

    Chapter 5 Tips and Troubleshooting Most problems with the TIP100 can be solved quickly by following the advice in this chapter. When you have a problem with your TIP100, there is usually a quick and simple solution. First make sure: The interface cables between your TIP100 interface unit and ●...
  • Page 26: If You Can't Connect To The Web Pages Of The Tip100

    If you can't connect to the web pages of the TIP100 Check that the IP address used by the TIP100 is in the same ● range as the IP address of the network you are using. For example if the TIP100 address voice announcement is 192.168.0.21 but the IP address of your PC is something like...
  • Page 27: If You Can't Hear Sound

    ● configuration setting Key Hold Time (Config Menu), set to a value of 1.0s or more. TIP100 Status Lights The TIP100 has two status lights on the front that indicate what is happening. If the TIP100 is The status light...
  • Page 28 Tips and Troubleshooting...
  • Page 29: Chapter 6 Learning More, Service, And Support

    Learning More, Service, and Support Chapter 6 Learning More, Service, and Support More information about the TIP100 interface unit is available in the on-screen help and on the Web. The following table describes where to get software and service information.
  • Page 30 Learning More, Service, and Support...
  • Page 31: Chapter 7 Connectors

    The connector marked TRANSCEIVER is a 25-way DB type socket connector located on the left hand side on the rear panel of the TIP100. It provides all the interface connections for the TIP100 and is typically accessed with one of several adaptor cables available to allow connection to either a handset or a transceiver and with and without RS232 data capability.
  • Page 32: Interface Cable Connectors

    Audio Out - Nominal 500mV P-P to ground with normal speech Interface Cable Connectors The 25-way TRANSCEIVER connector on the TIP100 provides all the interfaces to connect the TIP100 to a range of peripherals with their own specific connectors. Connectors...
  • Page 33 The following sections describe the various connectors used on these interface cables. Handset Plug Connects the TIP100 to a NGT Transceiver handset socket. Pin No. Function Signal levels Sensing Input +5 V standby power or +9 V handset power Data – Input/Output...
  • Page 34 Sleeve Audio - Up to 5V P–P depending on volume level Speaker Socket Provides a connection for a speaker to be connected to the TIP100. Pin No. Function Signal levels Speaker + Up to 5V P–P depending on volume level...
  • Page 35 RS232 Plug (optional) At the transceiver side, the optional interface cable for data use provides a 9-way DB style plug with a pin out similar a PC RS232 connector. Equipment that normally plug in directly to a PC RS232 connector can be plugged in on this plug. Pin No.
  • Page 36 Connectors...
  • Page 37: Chapter 8 Specifications

    Specifications Chapter 8 Specifications This chapter includes specifications for the TIP100. Network Network Connection RJ-45 10/100Mbit/s Ethernet with Link and Activity LED Network Protocols TCP/IP, UDP, HTTP, ICMP, SNMP, Supports BootP, DHCP and Auto IP Integrated web server for configuration and update functions...
  • Page 38: Compliance

    Compliance Certifications C-Tick RoHS compliant (lead free) Specifications...
  • Page 39: Index

    Index Front Panel........Transceiver......5 LINK........4 PWR........29 PTT........4 Rear Panel........RESET........4 LAN........5 Reset button....9, 23 PWR........5 STATUS........4 TRANSCEIVER.......5 TX........4 Service........27 LAN.........29 Settings........Network........Factory default......4 Address........Setup........9 Announcement...7, 8, 9, 10, Handset......9, 11 17, 23 Interface Mode....14 DHCP..7, 9, 10, 14, 17 Transceiver.....9, 10 MAC......14 Speaker....3, 7, 8, 9, 25...
  • Page 42 Through IP Pty. Ltd. 27 Rostrevor Avenue Rostrevor SA 5073 Australia www.through-ip.com 70-0100 Issue 17 Nov 2011...

Table of Contents