Lenovo ThinkCentre 7515 Hardware Maintenance Manual page 65

Machine types: 7515, 7522, 7523, 7560, 7569, 7610, 7611, and 7705
Hide thumbs Also See for ThinkCentre 7515:
Table of Contents

Advertisement

Diagnostic error code
001-198-XXX
System test aborted
001-199-XXX
System test failed, cause unknown
001-250-XXX
System ECC error
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System DMA error
001-260-XXX
001-264-XXX
System IRQ error
001-268-XXX
System IRQ1 failure
001-269-XXX
System IRQ2 failure
001-270-XXX
System IRQ3 failure
001-271-XXX
System IRQ4 failure
001-272-XXX
System IRQ5 failure
001-273-XXX
System IRQ6
(diskette drive) failure
001-274-XXX
System IRQ7 failure
001-275-XXX
System IRQ8 failure
001-276-XXX
System IRQ9 failure
001-277-XXX
System IRQ10 failure
FRU/Action
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 51
2. Flash the system and retest. See
"Updating (flashing) BIOS from a disc"
on page 278
3. Go to "Undetermined problems" on page
81
1. Go to "Undetermined problems" on page
81
2. Flash the system and re-test
3. Replace component under function test
System board
System board
System board
1. Device on IRQ1
2. System board
1. Device on IRQ2
2. System board
1. Device on IRQ3
2. System board
1. Device on IRQ4
2. System board
1. Device on IRQ5
2. System board
1. Diskette Cable
2. Diskette drive
3. System board
1. Device on IRQ7
2. System board
1. Device on IRQ8
2. System board
1. Device on IRQ9
2. System board
1. Device on IRQ10
2. System board
Chapter 7. Symptom-to-FRU index
59

Advertisement

Table of Contents
loading

Table of Contents