Sanitizing The Unit; Cleaning The Filter And Condenser (Quarterly) - Cornelius JETSPRAY JS7 Owner's Manual

Visual display dispenser series
Hide thumbs Also See for JETSPRAY JS7:
Table of Contents

Advertisement

JetSpray JS7 Owner's Manual

Sanitizing the Unit

After cleaning, add one gallon of water at a temperature of between 75°F (24°C) and 100°F (38°C) to the bowl. Mix
approved powdered chlorine sanitizer* according to manufacturers instructions. When dissolved, pour into bowl.
Replace the lid and run the unit for two or three minutes. Shut off the unit and drain the contents through the pinch
tube valve.
*Kay-5 sanitizer or equivalent powder or liquid sanitizer.
!
CAUTION:
Do not run the refrigeration system while sanitizing the unit.
C
F
LEANING THE
ILTER AND
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify
all power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1. Turn off the spray switch and unplug the power cord from the wall socket.
2. Remove back panel screws and remove the back panel by pulling out the bottom of the panel.
3. Clean the condenser with a vacuum cleaner or brush, being careful not to damage the condenser. Make
sure no loose dirt goes into the dispenser.
4. Clean the filter by running a stream of hot water through it. Filter does not need to be removed from the grill
to clean it.
5. Allow the filter to dry before replacing it.
6. Replace the back panel, placing the top edge up under the condensate tray and pushing it in at the bottom.
7. Reinstall the back panel screws.
8. Plug the power cord back into the wall socket and turn on the spray switch.