23.03.2000 / Page 2
Doc. No: 4812 712 15274

Technical data

Dimensions
Height
Width
Depth
Weight
Without packing
Main connection
Voltage
Frequency
Power consumption
Fuse rating
Drum
Volume
Door wide
Wash spin
Ramp spin
Speed spinning
Capacity of dry laundry
Cotton/coloured laundry
Cotton rapid
Easy care
Easy care rapid
Delicate
Wool
Pressostat for washing-machine
Level1
Switching point
Reset
Level2
Switching point
Reset
Overflow
Switching point
Water column drum
Level2
Switching point
Overflow
Switching point
AWT 4105
8561 410 10450
85
cm
40
cm
60
cm
61
kg
230
V
50
Hz
2.3
kW
10
A
42
l
210
mm
54
rpm
95
rpm
1000
rpm
5/ 4,5
kg
3
kg
2.5
kg
1.5
kg
1.5
kg
1
kg
32 ± 5
mmWc
15 ± 5
mmWc
60 ± 5
mmWc
33 ± 5
mmWc
280 ± 20 mmWc
50 ± 5
mm
285 ± 20
mm
Whirlpool Europe
Customer Service
Nominal current
Contacts:
11 - 12
11 - 14
21 - 12
21 - 24
21 - 26
Contactsystem:
11 - 12 - 14
21 - 22 - 24
21 - 26
Door lock
Lock time (0-85˚C)
Unlock time after 30"on
Nominal voltage
Nominal current contacts:
4 - 5
Heating element
Kind of heating
Nominal voltage
Nominal power
Heat conductor
resistance R 20
Water inlet valve
Water temperature max.
Rated flow > 1 bar
Pressure range
Nominal voltage
Frequency
Starting voltage (0.2-10 bar)160
Nominal current
Nominal power
Nominal resistor (20˚C)
Drain pump (synchronus)
Nominal voltage
Nominal current
Nominal consumption
Frequency
Resistor (coil)
Motor protection
Capacity (1.25m height)
S E R V I C E
4 (4)
A
4 (4)
A
4 (4)
A
16 (4)
A
1 (1)
A
jump contacts
jump contacts
slow action contacts
< 5"
70 ± 30"
250
V
16 (4)
A
Tubular heating element
230
V
2050
W
Ω ± 5%
25,8
80
˚C
l/min. ± 10%
8
0.2 - 10
bar
220 - 240 V
50
Hz
V
40
mA
8.8
VA
kΩ ± 10%
3.8
230
V
0.3
A
34
W
50
Hz
Ω ± 7%
162
no
15 ± 2
l/min

Hide quick links:

Advertisement

loading