Ignition Module - Testing; Ignition Module And Flywheel - Husqvarna 357XP/G Workshop Manual

Hide thumbs Also See for 357XP/G:
Table of Contents

Advertisement

Repair instructions
3
Fit a new recoil spring. Lubricate the recoil spring
with light oil.
4
Fit the bolt through the centre of the pulley and
tighten to a torque of 2–3 Nm.
Tension the recoil spring, see "Tensioning the recoil
spring".
Starter assembly – refitting
1
Position the starter assembly on the crankcase and
tighten the bolts to a torque of 2.5–3.5 Nm.
22
– English
Ignition module – testing
If there is a fault in the ignition system the ignition
module must be tested before the ignition system
is removed.
Test the ignition module as follows:
• Connect a test spark plug 502 71 13-01 to the
ignition lead and clip the test spark plug onto the
cylinder.
• Turn the engine over using the starter cord.
• If the test spark plug produces a spark the
ignition module is OK.
Ignition module/flywheel – removal
1
Remove the cylinder cover. Disconnect the HT
lead, remove the spark plug and fit piston stop
502 54 15-01 in its place. Take off the starter
assembly, release the leads from the cable guide
and remove it.