This Fan may be operated by the Manual Controls located on top of
the unit (as shown in Figure 5) or by the Remote Control (shown in
Figure 6).
1. Place the Fan on a firm and level surface.
CAUTION:
Plastic or rubber tabs, like the feet on this unit, may
stick to furniture surfaces and/or hardwood floors.The unit may leave
a residue that could darken, stain or leave permanent blemishes
on the finish of certain furniture surfaces, including wood surfaces,
and/or hardwood floors.
2. Plug the cord set into a 120 volt outlet.
Be sure that the plug fits tightly into outlet.
When plugs fit loosely into receptacles, they may slip
partially or completely out of the receptacle with only
the slight movement of the attached cord. Receptacles
in this condition may overheat and pose a serious fire
hazard; if covered by a curtain or drape, the fire hazard
is even greater.
3. Turn the Fan ON by pressing the Power Button ( ).
4. SPEEDS: Press the Fan Speed Button ( ) to desired speed
setting. Each time the Fan Speed Button is pressed, the speed
will change from Low (1), to Medium (2), to High (3). When intially
plugged in, the Fan will be in Low Speed. When the Fan is turned
OFF and ON again, the unit will resume the speed at which it was
turned OFF.
5. OSCILLATION: Press the Oscillation Button ( ) to start and
stop the oscillation function.
6. TIMER: The timer function allows the unit to be set to operate
for a length of time from 1/2 hour to 7 1/2 hours, in increments
of a 1/2 hour. Press the Timer Button ( ) to set the length of
time desired. Each time the timer button is pressed, the time is
increased by 1/2 hour. After reaching 7 1/2 hours, pressing the
timer button once more will reset the Fan to continuous running.
The lights on the front of the unit will light up appropriately with
the length of time that the Fan is set for.
7. IONIZER: The ionizer function on this Fan will operated within
any speed mode. Press the Ion Button (
I N
) once to turn this
function on and a second time to turn it off. The Fan must be ON
for the ionizer to be functional. When the ionizer is turned on this
will assist in the purification of the room air.
8. To turn the Fan OFF, press the Power Button ( ) and unplug the
unit from the electrical outlet.
Rev. D 9/07
MODEL 2534
Figure 5
4
Tamaño real de tornillos
4 por ventilador
4 por ventilador
ARMADO
1. Para facilitar el armado, recueste el Ventilador de modo que la
parrilla negra y el tablero de control den hacia arriba.
2. Localice el Cable Eléctrico en la parte inferior del Ventilador.
Coloque el Cable Eléctrico en los Canales Para Cable de los
Soportes De Columna. Encaje firmemente los Soportes De
Columna el uno con el otro de modo de formar un Conjunto De
Soportes De Columna. (Figura 1)
Remote Storage
3. Una el Conjunto De Soportes De Columna a la Base Del Motor
con (4) Tornillos M5 de 1/2" de largo. Cerciórese de alinear la
Llave del Conjunto De Soportes De Columna con la Muesca
Localizadora de la Base Del Motor. (Figura 1)
Conjunto De Soportes De Columna
Muesca
Localizadora
Soportes De
Columna
Cable
Eléctrico
Canales Para
Cable
4. Arme las Bases de Soporte, introduciendo las Copas en la Base
de Soporte A en los Orificios De Copas de la Base de Soporte
B. Pase el Cable de Electricidad por el orificio grande en el centro
del Conjunto de la Base de Soporte. (Figura 2)
Conjunto de la Base de Soporte
Cable
Eléctrico
Base de
Soporte B
2534ES
Rev. D 9/07
MODELO 2534
5. Fije los Tornillos (4) #8 X 1/2" en los cuatro orificios que se
encuentran en la parte inferior de la base. (Figura 3)
6. Alinee el Conjunto de la Base de Soporte con el Soporte de
Conjunto de la Base de Soporte
Conjunto
de la Base
de Soporte
2 por ventilador
#8 X 1/2"
Tornillos
Columna,cerciorándose de que el canal del cable en la parte
inferior de la base de soporte esté orientado hacia la parte posterior
del Ventilador. Ensamble el Conjunto de la Base de Soporte con
el Conjunto del Soporte de Columna utilizando los Tornillos M5
de (4) 1" de largo. Jale con cuidado toda holgura excesiva del
Cable de Electricidad e introdúzcala por el Canal Conductor de
Cable. (Figura 4)
Base Del
Motor
Conjunto
de la Base
de Soporte
Llave
Tornillos
M5 de 1/2"
Soportes De
Columna
Figura 1
M5 X 1"
Tornillos
Eléctrico
- Vista des de Arriba
Base de
Soporte A
Copas
Figura 2
9
- Vista des de Abajo
Cable
Eléctrico
Figura 3
Conjunto De
Soportes De
Columna
Canal
Conductor
de Cable
Cable
Figura 4
2534ES

Advertisement