Potterton Sirius two WH Instruction Manual page 15

90 & 110 kw
Table of Contents

Advertisement

(a)
(b)
ZONE 1 HEATING PARAMETERS
P01
700
*Operating mode (0=Frost Protection, 1=Timed, 3=T.comfort)
P02
712
*Reduced ambient temperature
P03
720
*"Kt" curve slope
P04
721
*"Kt" curve drift
P05
726
*"Kt" curve adaptation (0=off)
P06
740
Flow temperature setpoint (minimum value)
P07
741
Flow temperature setpoint (maximum value)
P08
742
*Enable modulating temperature if set = "---"
P09
750
*Room influence ("---" = disabled)
P10
834
*Opening/Closing speed of mix valve
ZONE2 HEATING PARAMETERS
P11
1000
*Operating mode (0= Frost Protection, 1=Timed, 3=T.comfort)
P12
1010
*Comfort room temperature
P13
1012
*Reduced room temperature
P14
1020
*"Kt" curve slope
P15
1021
*"Kt" curve drift
P16
1026
*"Kt" curve adaptation (0=off)
P17
1040
Flow temperature setpoint
P18
1041
Flow temperature setpoint (maximum value)
P19
1042
*Enable modulating temperature if set = "---" (flow temp. setpoint if P63=0)
P20
1050
*Room influence ("---" = disabled)
P21
1134
*Opening/Closing speed of mix valve
DHW PARAMETERS
Operating mode in DHW (with Remote Control)
P22
1620
0=always enabled, 1=according to hourly heating programme,
2= according to hourly DHW programme.
Anti-legionella function Disabled
P23
1640
0=disabled, 1=periodic (depending on P24)
Periodic anti-legionella function enable (
P24
1641
1=daily, 2..6=intervals of 2..6 days, 7=once a week
P25
1663
Circulation temperature setpoint (additional DHW pump)
P26
5470
Preheating time for DHW circuit (1=10' -- 144=1440')
BOILER PARAMETERS
P27
2243
Minimum boiler off time
P28
2217
Frost Protection setpoint
P29
2250
Pump post-circulation time
P30
2441
Max. fan speed (heating)
P31
2455
Minimum boiler off differential
SOLAR PLANT PARAMETERS (with accessory Expansion Unit)
P34
3810
Temperature - on differential
P35
3811
Temperature - off differential
P36
3830
Collector start function ("---" = disabled)
P37
3850
Solar panel manifold overheating protection ("---" = disabled)
P38
5050
DHW charging temperature max
P39
5051
Maximum temperature of storage tank
CONFIGURATION
P40
5700
Not used (Do NOT change this parameter)
P41
5710
Zone 1 heating circuit (1=enabled)
P42
5715
Zone 2 heating circuit (1=enabled)
P43
5730
DHW sensor (1=Tank sensor, 2=Thermostat, 3=instantaneous sensor)
P44
5890
Not used (Do NOT change this parameter)
P45
5931
*BX2 sensor input (first auxiliary sensor – section 11)
P46
5932
*BX3 sensor input (second auxiliary sensor – section 11)
P47
5977
*Input H5 (multifunction input – 18=Room thermostat)
P48
6020
*Configuration of accessory Expansion Unit
P49
6024
Function input EX21 module 1 (configuration of HC Safety Thermostat)
P50
6046
Function input H2 module 1 (multifunction input)
P51
6097
Sensor type collector (1= NTC, 2= Pt 1000)
P52
6110
Building time constant
P53
6220
Software version
P54
6600
LPB device address
P55
6601
LPB segment address
P56
6640
Clock time source
(main zone)
(with accessory Expansion Unit)
only if P23 =1)
15
Factory
Minimum Maximum
setting
-
3
0
°C
16
4
-
1,5
0,1
-
0
- 4,5
-
1
0
°C
25
8
°C
80
25
°C
80
25
%
50
1
S
180
30
°C
3
0
°C
20
4
°C
16
4
-
1,5
0,1
-
0
- 4,5
-
1
0
°C
25
8
80
°C
25
°C
80
25
50
%
1
s
180
30
0
-
0
-
0
0
-
7
1
°C
45
8
min
0
0
min
3
0
°C
5
-20
min
3
0
rpm
xxx
0
°C
10
0
°C
8
0
°C
4
0
min
---
5
°C
---
30
°C
65
8
°C
90
8
-
---
---
-
1
0
0
-
0
1
1
33
-
0
-
0
0
0
-
0
-
18
0
0
-
0
-
0
0
-
0
0
-
2
1
h
15
0
-
---
0
-
1
-
0
-
0
7108686.02 (1-11/12)
3
35
4
4,5
1
80
80
80
100
873
3
35
35
4
4,5
1
80
80
80
100
873
2
1
7
80
144
20
20
240
8000
20
40
40
60
350
95
95
---
1
1
3
43
19
19
32
7
1
58
2
50
99
16
14
3