Cleaning And Maintenance - Desa L32LHN Owner's Manual

Unvented (vent-free)
Table of Contents

Advertisement

WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burners and
circulating air passageways
of heater clean. Inspect these
areas of heater before each use.
Have heater inspected yearly
by a qualified service person.
Heater may need more frequent
cleaning due to excessive lint
from carpeting, pet hair, bedding
material, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
BURNER INjECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these
holes clear of dust, dirt, lint and pet hair.
Clean these air inlet holes prior to each
heating season. Blocked air holes will create
soot. We recommend that you clean the unit
every three months during operation and
have heater inspected yearly by a qualified
service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store or
home center may carry compressed air in a
can. If using compressed air in a can, please
follow the directions on the can. If you don't
follow directions on the can, you could dam-
age the pilot assembly.
1. Shut off unit, including pilot. Allow unit to
cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet
holes on injector holder for dust and dirt
(see Figure 39).
3. Blow air through the ports/slots and holes
in the burner.
26

CLEANING AND MAINTENANCE

www.desatech.com
4. Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint or pet
hair with a soft cloth or vacuum cleaner
nozzle.
5. Blow air into the primary air holes on the
injector holder.
6. In case any large clumps of dust have now
been pushed into the burner repeat steps
3 and 4.
Clean pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot
assembly. There is a small pilot air inlet hole
about 2" from where the pilot flame comes out
of the pilot assembly (see Figure 40). With the
unit off, lightly blow air through the air inlet
hole. You may blow through a drinking straw
if compressed air is not available.
Burner
Tube
Figure 39 - Injector Holder On Outlet
Burner Tube (Burner will vary by model)
Pilot Air
Inlet Hole
Figure 40 - Pilot Inlet Air Hole (Your pilot
assembly may vary from pilots shown)
CLEANING LOGS
• If you remove logs for cleaning, refer to
Installing Logs, page 16, to properly replace
logs.
• Replace log(s) if broken or chipped (dime-
sized or larger).
Injector
Holder
Primary
Air Inlet
Holes
Pilot Air
Inlet Hole
115254-01B