VIEWING THE STATUS INFORMATION
After replacing the Main Board, LCD Panel, or TCON Board, you MUST
UPDATE the SOFTWARE to the latest version. Verify the latest software is
installed before proceeding to the service adjustments.
3.
Press
until Status Information is selected, then press
Main Micro
SW Version
NVM Version:
Boot Version:
Panel Version:
PQ Version:
AQ Version:
4.
Verify the latest software version is installed.
5.
Do one of the following:
a. If the latest software is installed, proceed to Changing the
LVDS Spectrum.
b. If the latest software is not installed, update the software and
then proceed to Changing the LVDS Spectrum.
CHANGING THE LVDS SPECTRUM
Verify before proceeding to the next step:
; Verified Status Information
KDL-32BX355/40BX455/46BX455
SECTION 5 - UPDATES AND ADJUSTMENTS
SONY_2012_TOSCA_1.04
1
0.01
V0.004
V1.00b
AQ1.001
until LVDS Spectrum (%) is selected.
6.
Press
Sound Adjustment
Wide Band Tuning
Range Scan...
.
Self diagnosis history
Status Information...
LVDS Spectrum(%0)
Panel Selection
SERIAL NUMBER EDIT
MODEL NAME EDIT
7.
Press
or
8.
Proceed to Selecting the LCD Panel
SELECTING THE LCD PANEL
Verify before proceeding to the next step:
; Verified Status Information
; Changed the LVDS Spectrum
9.
Press
until Panel Selection is selected.
Sound Adjustment
Wide Band Tuning
Range Scan...
Self diagnosis history
Status Information...
LVDS Spectrum(%0)
Panel Selection
SERIAL NUMBER EDIT
MODEL NAME EDIT
Service Mode
>>
>>
>>
>>
>>
<[
50
<[
T315XW04_V3
1322132
KDL-32BX355
[</>]Set [Menu] Exit
to change the data value.
Service Mode
>>
>>
>>
>>
>>
<[
50
<[
T315XW04_V3
1322132
KDL-32BX355
[</>]Set [Menu] Exit
]>
]>
]>
]>
27