Parts List
Rheostat
Instrument
Section
Head
Attachment
Light
Chrome Ring
Intensity
Control
Battery
Ring
On/Off
Section
Button
71960
Low
Battery
Indicator
Figure 1
OPERATING INSTRUCTIONS
1.
Connect instrument head to the handle.
2.
Depress On/Off Button on Rheostat Section and rotate the Light Intensity Control
Ring clockwise (CW). To intensify light, continue to rotate until stop is reached
(Figure 1).
3.
To turn off, rotate counter clockwise (CCW). Button will click when fully off. Turn
fully off after each use to ensure maximum on-time from the battery.
CHARGING INSTRUCTIONS
7114x Universal Charger
1.
Insert the handle into the Well. Charge for 24 continuous hours to charge a dead
battery (less to top off).
2.
Fully charged handles may remain in the Charger if desired.
3.
Charging the Battery after partial discharge does not negatively affect overall
battery memory (unlike Ni-Cad cells).
71110 Desk Charger (obsolete) and Ophthalmic Stands
See well adapter instructions for installing well adapter(s). Once adapters are installed,
follow charging procedures indicated under the 7114x Universal Charger.
NOTE: The Battery Section is not shipped fully charged. For maximum performance
charge the Battery Section for 24 hours when new or after a long period of inactivity.
LOW BATTERY INDICATOR
1.
The Low Battery Indicator will illuminate several minutes before handle shuts off
depending on the age of the battery (Figure 1).
2.
Once the battery is fully discharged, the Low Battery Indicator may flicker.
INSTALLING 71980 WELL ADAPTERS INTO THE 71110
DESK CHARGER
1.
Insert the Well Adapter into one of the Handle Receptacles in the Desk Charger.
Be sure to insert the Adapter until it is fully seated. Once the Well Adapter has
been installed, it does not need to be removed (Figure 2).
2.
One or two Well Adapters may be used with the Desk Charger.
BATTERY REPLACEMENT
Removing the old Battery Section:
1.
Hold the instrument handle firmly by the Battery Section.
2.
Turn the Rheostat Section Counterclockwise until it detaches from the Battery
Section (see figure 2).
Installing A New Battery Section
1.
Insert the Rheostat Section into the new Battery Section.
2.
To connect the two sections, turn the Rheostat Section clockwise until tight (see
figure 2).
3.
Verify the Rheostat Section is secure on the Battery Section of the instrument
handle.
Figure 2
CLEANING
The cleaning of all Welch Allyn power handles and chargers is easily accomplished by
wiping the external surface with a cloth dampened with a mild detergent and water
solution, 70% isopropyl alcohol, or a 10% bleach solution (by volume). Do not immerse.
NOTE: Excess solution entering the assembly could damage internal components. Use
caution to ensure cloth is not saturated with solution.
Do not sterilize the 719 Series Power Handle or Well Adapter.
Battery Recycling
Welch Allyn now employs the services of an agency which can disassemble and recycle
all components of rechargeable batteries so that nothing gets landfilled or incinerated.
Should you wish to dispose of your expended Welch Allyn rechargeable battery via
recycling (in the U.S. and Canada only), please send to:
Welch Allyn
Welch Allyn Canada
RECYCLE BATTERY
RECYCLE BATTERY
4341 State Street Road
160 Matheson Blvd. East
Skaneateles Falls, NY
Mississauga, Ontario
13153-0220
CANADA L4Z 1V4
For locations outside the U.S. and Canada consult your local recycling authority for
correct disposal of batteries.
SPECIFICATIONS
(Specifications and design may change without notice)
Handle
Model Number:
71911
Dimensions:
5.4" Long x 1.125" Diameter (Max.)(137mm x 28.6 mm)
Weight:
4.5 oz. (128 g)
Typical Charge Time:
24 hours (fully discharged)
Typical Discharge Time:
110 minutes (for new battery)
Approvals:
Complies with: IEC 60601-1, CAN/CSA C22.2 No 125 and
UL544
When used with 71980 Well Adapter and 711 series
Desk Charger
US
Equipment Classification:
TYPE BF Equipment.
Equipment Classification
(All Charger Model Numbers)
Double Insulation
Equipment Classification
(All System Components)
IXPO
Equipment not protected against the ingress of water.
Operating Mode:
Continuous Operation
NOTE: This product complies with current required standards for electromagnetic
interference and should not present problems to other equipment or is affected by other
devices. As a precaution, avoid using this device in close proximity to other equipment.
Environment
(
All System Components
)
Transport/Storage:
-20°C ~ 49°C, 95% R.H. Max, 500hPa - 1060hPa, Altitude
Operating:
10°C ~ 40°C, 95% R.H. Max, 500hPa - 1060hPa, Altitude
The CE mark on this product indicates it has been tested to and
conforms with the provisions noted in the 93/42/EEC Medical Device
Directive.
Authorized European Representative:
European Regulatory Manager
Welch Allyn, Ltd.
Navan Business Park
Dublin Road
Navan, County Meath, Republic of Ireland
Telephone: 353 46 67700
Fax: 353 46 27128
SERVICE AND WARRANTY
Service Information
Other than battery replacement, this equipment contains no user servicable parts. Return
to a Welch Allyn authorized service center for service.
For Technical Support or to obtain return instructions, please contact your nearest Welch
Allyn service center listed below:
Welch Allyn, Inc.
Welch Allyn, Ltd - Canada
4341 State Street Road
160 Matheson Blvd. E., Unit #2
Skaneateles Falls, NY 13153-0220
Mississauga, Canada L4Z 1V4
Telephone: 800-535-6663
Telephone: 905-890-0004
Fax: 315-685-4653
Fax: 905-890-0008
Welch Allyn, Ltd. - UK
Welch Allyn, GmbH PSC
Cublington Road
Zollerstrasse 2-4
Aston Abbotts
D72417 Juningen, Germany
Buckinghamshire England HP22 4ND
Telephone: 011-49-7477-927186
Telephone: 011-0207-365-6780
Fax: 011-49-7477-927293
Fax: 011-0207-365-9694
Welch Allyn, LTD - Singapore
Welch Allyn China Service Center
300 Beach Road
Room 708 Central Plaza
The Concourse #25-08
No. 277 Huang Pi Bei Rd.
Singapore 199555
Huang Pu District
Telephone: 011-656-291-0882
Shanghai 20003, China
Fax: 011-656-291-5780
Telephone: 011-86-21-63279631
FAX: 011-86-21-63279632
Welch Allyn, Ltd. - Australia
The Metro Centre Unit 5
38-46 South Street
Rydalmere NSW 2116, Australia
Telephone: 011-(612) 9638-3000
Fax: 011-(612) 9638-3500
Warranty
The 719 series Power Handle is guaranteed by Welch Allyn against all manufacturing
defects. Welch Allyn will repair or replace, free of charge, any parts of its own
manufacture proven to be defective through causes other than misuse, neglect, damage
in shipment, or normal wear.
Welch Allyn warrants that the Welch Allyn 71960 Battery Section will perform to original
specifications during the two years from the date of manufacture, when used with the
Welch Allyn 719 series Power Handle. This warranty does not apply to the use of the
71960 battery in other products. A defective battery will be replaced if it fails within two
years of the date of manufacture.

Advertisement