ViewSonic VT2756-L User Manual page 49

Professional lcd tv display
Hide thumbs Also See for VT2756-L:
Table of Contents

Advertisement

Other Information
Reply (Hex Format)
Name
Length
Hex
0x34
Get-function table
Get
Length ID
Function
Get-Contrast
8
Get-Brightness
8
Get-Sharpness
8
Get-Color
8
Get-Tint
8
Get-Volume
8
Get-Mute
8
Get-Input select
8
Get-Power
8
status: ON/
STBY
Get-Remote
8
control
Get-Power lock
8
Get-Button lock
8
Get-Menu lock
8
Get-Setup
8
wizard
Get-ACK
8
3.3 Remote Control Pass-through mode
When PC sets the TV monitor to Remote Control Pass through mode, the TV shall send a 7 bytes
packet (followed by "CR") in response to RCU button activation. Note, that in this mode the RCU
shall have no effect on the TV function. For example: "Volume+" will not change the volume in the
LCD but only sends "Volume+" code to PC over the RS232 port.
ID
Command
Type
0x30
0x2D
0x35
Command
Command
Type
Code (ASCII) Code (Hex)
g
a
g
b
g
c
g
d
g
e
g
f
g
g
g
j
g
l
g
n
g
o
g
p
g
q
g
s
g
z
40
CR
0x0D
Response Range
(Three ASCII
bytes)
61
000 ~ 100
62
000 ~ 100
63
000 ~ 100
64
000 ~ 100
65
000 ~ 100
66
000 ~ 100
67
000: Off
001: On (muted)
6A
000~
6C
001: ON
000: STBY
6E
000: Disable
001: Enable
002: Pass
through
6F
000: Unlock
001: Lock
70
000: Unlock
001: Lock
71
000: Unlock
001: Lock
73
000: Disable
001: Enable
7A
000
Comments