8-4 Defrost Sensor Error (Er dS)
No
1
Check for a loose connection.
2
Check the Orange to Orange.
Check the Brown to Brown.
Checking flow
<CON6>
Result & SVC Action
Result
0 Ω
Short
OFF
Open
Other
Normal
<Temperature table-3>
(1) To (2)
-22°F / -30°C
-13°F / -25°C
-4°F / -20°C
5°F / -15°C
14°F / -10°C
23°F / -5°C
32°F / 0°C
※ The sensor is sensing the temperature.
For example, 23㏀ indicates -4°F.
- 30 -
SVC Action
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-3)
Result
40 ㏀
30 ㏀
23 ㏀
17 ㏀
13 ㏀
10 ㏀
8 ㏀