PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

CALIBRATE FLOW

This function allows the operator to enter the
actual flow rate of the sprayhead and the bypass for the
brewer by dispensing both separately for one minute.
The volumes are then entered in ounces per minute
(OZ/M).
Procedures to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated in ounces,
and with a minimum capacity of 60 ounces, be-
neath the funnel.
2. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Press and
release the ® pad until the display reads CALI-
BRATE FLOW ?.
3. Press and release YES to advance to the SPRAY
HEAD CAL? function screen. (Pressing NO in the
CALIBRATE FLOW screen will advance to the next
function screen, BREW COUNTERS).
4. Press and release the YES pad. The display should
read CONTAINER READY? If the container is un-
der the funnel, press YES. The display should read
CALIBRATE SPRAY .. PRESS BREW TO START.
5. Press and release the
read CALIBRATE SPRAY .. 60 SEC TO FINISH.
The 60 second timer on the display will count
down to zero. When the counter reaches zero, the
display will change to OZ., along with a number
signifying ounces per minute.
6. Measure the amount of water in the container and
using the (-) or (+) pads, adjust the amount on the
display to match the amount in the container. Then
press DONE.
7. The display should now read NEW SPRAY FLOW,
along with the correct flow rate of the sprayhead in
ounces per minute. After about 5 seconds, the
display will return to the CALIBRATE FLOW screen.
8. To exit the CALIBRATE FLOW program, press NO
to advance to the next function screen, or press
and release the
switch panel to exit the CALIBRATE FLOW func-
tion and return to the MAIN SCREEN.
pad. The display should
pad located on the front