Electrical Adjustments
Group/
Item Name
Item
9 Temp C-A Warning(Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
1 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
15
(Temp)
Temp B Warning Offset
16
(Temp)
Temp C Warning Offset
17
(Temp)
Temp B-A Warning Offset
18
(Temp)
Temp C-A Warning Offset
19
(Temp)
Temp A Warning Offset
0
(Time)
Temp B Warning Offset
1
(Time)
Temp C Warning Offset

(Time)
Temp B-A Warning Offset
3
(Time)
Temp C-A Warning Offset
4
(Time)
Group
Fan control range Setting (temp./Voltage)
254
10 Normal Fan Control Min Temp
Normal Fan Control Max
11
Temp
1 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan Min
15 Normal Fan Max
16 Normal Fan3 Min
17 Normal Fan3 Max
0 Eco Fan Control Min Temp
1 Eco Fan Control Max Temp
 Eco Fan1 Min
3 Eco Fan1 Max
4 Eco Fan Min
5 Eco Fan Max
6 Eco Fan3 Min
7 Eco Fan3 Max
Group
Fan Start/cooling Setting
255
0 Fan1 Initial Volt
1 Fan Initial Volt
 Fan3 Initial Volt
4 Fan1 Cooling Speed
5 Fan Cooling Speed
6 Fan3 Cooling Spees
8 Cooling Time L1
9 Cooling Time L
10 Temp Error Cooling Time
11 OnStart Cooling Start Thresh-
old
1 After shutdown cooling
Group
Fan lamp Voltage down Setting
256
0 Lamp Voltage
Function
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco(Panel)
Temp. C to judge the Temp Error at
Eco(Panel)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Senser Control Start/End Tem.p
at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Senser Control Start/End Tem.p
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time stting at Fan Mode L (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x
30 sec)
Cooling after shutdown (0: No, 1: Yes)
Current Lamp Voltage (0.1V)(Read
only)
Initial
100
100
100
100
4
4
41
41
58
58
58
58
60
60
60
60
100
100
100
100
100
100
100
100
5
5
5
0
0
3
3
3
3
3
HiLand-
HiLand-
Normal Ceiling
Normal
Ceiling
33
33
33
33
38
38
37
37
75
80
90
90
15
15
135
135
68
75
80
80
80
80
80
80
80
85
90
90
135
135
135
135
30
30
33
33
38
38
37
37
55
60
80
80
115
10
15
15
45
45
55
55
50
50
60
60
70
75
80
80
15
15
15
15
55
55
55
130
130
130

3
3
38
1
-
-44-
range
Note
0-100
30-100
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
1-15
1-15
1-15
0-100
0-1
0-55