COMPONENTS ® ELECTRONIC AIR CLEANER MODEL 5000 Figure 1 PLEAT SPACERS OUTER HOUSING #501 MEDIA INNER HOUSING CONTROL ELECTRODE Handle POWER PACK / DOOR ASSEMBLY IONIZER FRAME Model 51...
Important The Model 5000 Air Cleaner is designed for systems with airflow up to 2000 cfm. If the furnace has more than one return air inlet connection, install one air cleaner in each. The air cleaner can be installed horizontally, vertically, or at an angle depending on furnace type.
IMPORTANT: Identify the outlet for “EAC USE ONLY” 11. Return power to the furnace/air handler. 12. Plug the Aprilaire Air Cleaner power cord into the outlet installed in step 10. 13. Check for proper operation when the furnace is run through heating and cooling cycles.
The inner housing assembly must be installed and the power pack / door assembly to the air cleaner must be fully closed. The unit should be plugged in and the power switch on the air cleaner door turned on. There are no other controls or settings required.
Page 7
TROUBLE SHOOTING GUIDE (CONTINUED) Figure 12 End Panel Conductive Rubber Strip 6. Inspect components to ensure the following (continued): c. The conductive rubber strip must be in contact with the conductive-coated tips of the media. See Figure 12. d. The nine ionizing wires must be clean, straight, and hooked onto the bus bar at one end and the ionizer frame at the other.
Page 8