Fig. 30: Connect the electrical cables to the connection terminals.
Example connection: with heater circuit-breaker, room temperature controller and a standard charge control system.
A1+, A2-
DC signal for charge control system
A1~, A2~
AC signal for charge control system
L1, L2, L3
Phase
LE
Fan control
LH
Additional heating control
LR
Charge regulator
L-R
Phase for charge regulator
L-SH
Phase for direct control
M1
Fan
N
Neutral conductor
N-R
Neutral conductor for charge con-
troller
N-R9
Neutral conductor for additional
heating
www.dimplex.de/en
Example connection: with heater circuit-breaker, room tem-
perature controller and a standard charge control system
N-SH
P1
PE
R1-R6
R7
R9
RTR
STR
TB
TF1
TR9
TRG
459462.66.01 · 10/14/B
FSR 15-35 / FSR 15-35 GS / FSR 15-35 GW
Neutral conductor for direct control
Intensity regulator for charge intensity
control
Protective conductor
Heating elements
Series resistor
Additional heating (accessories)
Room temperature controller (external)
Safety temperature controller
Safety temperature limiter
High temperature gauge
Temperature controller for additional
heating
Temperature controller for ventilation
grille
EN-35