Securing The Unit To The Wall; Deciding The Position; Deciding The Wiring Route - Bosch Tronic 3000 C Pro US12 Installation And Operating Instructions Manual

Electric water heaters
Hide thumbs Also See for Tronic 3000 C Pro US12:
Table of Contents

Advertisement

Available languages

Available languages

US
4.5

Securing the unit to the wall

4.5.1

Deciding the position

B If being used in a public place, position the unit out of
reach to discourage vandalism.
B Mount the unit onto a flat section of wall, well away
from any potential splashes of water or spray.
B Position the unit as shown (Fig. 4).
Remember to keep the length of hot water pipe to a
minimum in order to save energy.
Hot
Cold
Fig. 4
Examples of installations
4.5.2

Deciding the wiring route

You have a choice of whether to feed the electric cable
through the cover bottom or through the back of the
unit,
B If it is going to be through the cover bottom, cut out
the plastic lug to expose the rubber sleeve (Fig. 5):
Fig. 5
Unit cover
B If it is going through the back of the cover unit, cut
through the grommet on the backplate with a sharp
knife. Make sure that you do not remove the grommet
from the backplate (Fig. 6):
B If the unit is to supply a sink, you can It it either above
or below the sink.
Cold
Hot
Show front view
Fig. 6
1
Grommet
2
Fixing holes
B Feed the cable through the grommet before you
mount the unit to the wall. If you are using an
approved cable fitting, remove the grommet.
WARNING:
B Unit must be mounted as shown in Fig. 4
with plumbing connection on the bottom.
Under no circumstances should the unit
be mounted differently.
Hot
1
Back of unit
Installation | 11
Cold
2
6 720 647 088 (2011/09)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tronic 3000 c proUs12

Table of Contents