Power LED blinking timing chart

1.
Subject
Information of LED Flashing timing chart.
2.
Contents
When abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
Blinking
times
Once
1
2
3
4
5
6
7
8
9
10
Blinking timing
4 sec
Light
No Light
Contents
INVERTER_SOS
FAN_SOS
BT_30V,SOUND 15V
PANEL 12V, HQ_ 3.3V
DTV_9V
MAIN_9V
SUB_5V
MAIN_5V
MAIN_3.3V
SOUND_SOS
HQ1L_SOS
11
Check point
DG BOARD
LCD PANEL
H BOARD
DG BOARD
H BOARD
AP BOARD,DG BOARD
AP BOARD
H BOARD, DG BOARD
AP BOARD
H BOARD, DG BOARD
AP BOARD
H BOARD, DG BOARD
DG BOARD
DG BOARD
H BOARD
DG BOARD
DG BOARD