Select the e-shredding algorithm

Select the e-shredding algorithm
Introduction
The e-shredding function allows you to securely erase jobs from the system. This prevents
unauthorised people from accessing deleted jobs.
You can select one of the following algorithms:
• [Gutmann].
All jobs on the system are erased in 35 overwrite passes.
• [DoD 5220.22-M].
All jobs on the system are erased in three overwrite passes.
• [Custom] allows you to define the number of passes manually.
The factory default is [DoD 5220.22-M].
NOTE
Only set the number of overwrite passes to a number higher than 1, if your security policy
requires it. An increase of passes can affect the performance.
Procedure
1.
Open the [Configuration] - [Connectivity] tab.
2.
Open the [E-shredding] - [E-shredding algorithm] settings.
3.
Click [Edit].
4.
Select the preferred method and save it.