Equipment Composition - Mitsubishi Electric CITY MULTI PUHY-400YMF-B Service Handbook

City multi series y, super y
Table of Contents

Advertisement

[3] Equipment Composition

A. Outdoor Unit
B. Branch Pipe Kit
Oil balance pipe 1
Distributer (gas)
Oil balance pipe 2
Distributer (liquid)
CMC-30A*
In the case of the PUHY-(P)YSMF-B, the CMC-30A is
necessary.
D. Indoor unit
Model
Cassette ceiling
1-way flow
2-way flow
Capacity
PMFY-P
PLFY-P
20
20VMB
20VLMD
25
25VBM
25VLMD
32
32VBM
32VLMD
40
40VBM
40VLMD
50
-
50VLMD
63
-
63VLMD
71
-
80
-
80VLMD
100
-
100VLMD
125
-
125VLMD
140
-
200
-
250
-
E. Option (panel)
Model
Decoration panel
Capacity
PMP-
20
25
32LW-F
40MB
32
40
40LW-F
50
63
-
63LW-F
80
100, 125
125LW-F
F. Remote controller
PAR-F25MA
PAC-FL31MA
ON/OFF –
CENTRALLY CONTROLLED
1Hr.
ON OFF
˚C
CHECK
CLOCK
FILTER
˚C
CHECK MODE
STAND BY
INDOOR UNIT
ERROR CODE
NOT AVAILABLE
TEST RUN
DEFROST
ADDRESS NO.
OA UNIT ADDRESS NO.
CLOCK
ON OFF
FILTER
CHECK
TEMP.
TIMER SET
TEST RUN
NETWORK
REMOTE CONTROLLER
PAR-F25MA
PUHY-(P)400·500YMF-B
Branch joint
CMY-Y102S-F CMY-Y102L-F
CMY-Y202-F
CMY-Y302-F
Ceiling
concealed
4-way flow
PLFY-P
PEFY-P
-
20VML
-
25VML
32VKM
32VML
40VKM
40VMH
50VKM
50VMH
63VKM
63VMH
-
71VMH
-
80VKM
80VMH
100VKM
100VMH
125VKM
125VMH
-
-
140VMH
-
-
200VMH
-
-
250VMH
CMP-
PLP-
-
3GB
6GB
PAC-SC30GRA
CHECK
TEST RUN
˚C
AM
PM
CENTRALLY CONTROLLED
AM
CHECK
ADDRESS
ON
OFF
PM
˚C
NOT AVAILABLE
COLLECTI V E
GROUP
ON/OFF
MODE
TEMP.
ON/OFF
CLOCK
FAN
VANE
STOP
START
GROUP
GROUP
HR.
MIN.
REMOTE CONTROLLER
PAC-SC30GRA
PUHY-(P)600·650·700·750
M
4-connection
CMY-Y104-E
M
Ceiling mounted
Wall mounted
built-in
PDFY-P
PKFY-P
20VM
20VAM
25VM
25VAM
32VM
32VGM
40VM
40VGM
50VM
50VGM
63VM
-
71VM
-
80VM
-
100VM
-
125VM
-
-
-
-
-
-
-
MJ-103MTRA
ON/OFF
˚C
FILTER
ON/OFF
CHECK MODE
TEST RUN
TEST RUN
ON/OFF
MODE
1
2
NOT AVAILABLE
DIRECTION
4
5
TEMP.
CLOCK/
PATTERN
VENTILATION
7
8
FILTER
REMOTE
TIMER
PROHIBITION
MODE
CENTRAL CONTROLLER
MJ-103MTRA
0
CHECK
TEST RUN
–22–
YSMF-B
Branch header
7-connection
CMY-Y107-E
Floor standing
Ceiling
suspended
Exposed
Concealed
PCFY-P
PFFY-P
PFFY-P
-
20VLEM
20VLRM
-
25VLEM
25VLRM
-
32VLEM
32VLRM
40VGM
40VLEM
40VLRM
-
50VLEM
50VLRM
63VGM
63VLEM
63VLRM
-
-
-
-
100VGM
-
125VGM
-
-
-
-
-
-
-
PAC-SC32PTA
S E T B A C K
S M T W T F S
SET
0
3
6
9
12
FAN SPEED
GROUP
12
15
18
21
24
3
SELECT
AIR
6
BACK
SCREEN
9
INS.
WEEKLY
DAILY
SET/MONITOR
TODAY
SETTING
SET BACK
ON
SETTING
RESET
DEL.
ENTER
ON
SET BACK
CLOCK
OFF
DAILY TIMER
OFF
PROGRAM TIMER
PAC-SC32PTA
10-connection
CMY-Y1010-E
-
-
-
-
-
-
-
PAC-SE51CRA
CENTRAL TEMP.CHECK
˚C
ON/OFF
TEMP.
PAC-SE51CRA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents