28. Technical data

Boiler model
LUNA HT
Category
DHW rated heat input
CH rated heat input
Reduced heat input
DHW rated heat output
CH rated heat output 75/60°C
CH rated heat output 50/30°C
Rated heat output 75/60°C
Rated heat output 50/30°C
Useful efficiency according to 92/42/CEE directive
Central heating system max. pressure
Expansion vessel capacity
Expansion vessel pressure
DHW system max. pressure
DHW system min. dynamic pressure
DHW system min. output
DHW production at ∆T=25 °C
DHW production at ∆T=35 °C
Specific output (*)"D"
Heating circuit temperature range
Domestic hot water temperature range
Type
Concentric flue duct diameter
Concentric air duct diameter
2-pipe flue duct diameter
2-pipe air duct diameter
Max. flue mass flow rate
Min. flue mass flow rate
Max. flue temperature
NOx class
Type of gas used
Natural gas feeding pressure
Propane gas feeding pressure
Power supply voltage
Power supply frequency
Rated power supply
Net weight
Dimensions
Protection-limit against humidity and water leakages (**)
(*) according to EN 625
(**) according to EN 60529
BAXI
, in its commitment to constantly improve its products, reserves the right to alter the specifications contained herein at any time and without previous warning.
S.p.A.
These Instructions are only meant to provide consumers with use information and under no circumstance should they be construed as a contract with a third party.
Ed. 3 - 12/05
kcal/h
kcal/h
kcal/h
kcal/h
kcal/h
height
width
depth
BAXI
36061 BASSANO DEL GRAPPA (VI) ITALIA
Via Trozzetti, 20
Tel. 0424 - 517111
Telefax 0424/38089
280
330
II
II
2H3P
2H3P
kW
28,9
34
kW
24,7
28,9
kW
9
9,7
kW
28
33
24.080
28.380
kW
24
28
20.640
24.080
kW
25,9
30,3
22.270
26.060
kW
8,7
9.4
7.480
8.090
kW
9,5
10.2
8.170
8.770
★★★★
★★★★
bar
3
3
l
8
10
bar
0,5
0,5
bar
8
8
bar
0,2
0,2
l/min
2,5
2,5
l/min
16,1
18,9
l/min
11,5
13,5
l/min
12,9
15,3
°C
25÷80
25÷80
°C
35÷60
35÷60
C13 - C33 - C43 - C53 - C63 - C83 - B23
mm
60
60
mm
100
100
mm
80
80
mm
80
80
kg/s
0,014
0,016
kg/s
0,004
0,005
°C
75
75
5
5
G20
G20
G31
G31
mbar
20
20
mbar
37
37
V
230
230
Hz
50
50
W
155
160
kg
45,5
46,5
mm
763
763
mm
450
450
mm
354
354
IPX5D
IPX5D
S.p.A.
1.120
1.240
II
II
2H3P
2H3P
-
-
12,4
24,7
4
7
-
-
-
-
12
24
10.320
20.640
13
25,9
11.180
22.270
3,9
6.8
3.350
5.850
4,2
7.4
3.610
6.360
★★★★
★★★★
3
3
8
8
0,5
0,5
-
-
-
-
-
-
-
-
-
-
-
-
25÷80
25÷80
-
-
60
60
100
100
80
80
80
80
0,006
0,012
0,002
0,003
73
73
5
5
G20
G20
G31
G31
20
20
37
37
230
230
50
50
145
150
44
45
763
763
450
450
354
354
IPX5D
IPX5D
code C603677
1.280
II
2H3P
-
28,9
9,7
-
-
28
24.080
30,3
26.060
9.4
8.090
10.2
8.770
★★★★
3
10
0,5
-
-
-
-
-
-
25÷80
-
60
100
80
80
0,014
0,005
75
5
G20
G31
20
37
230
50
155
46
763
450
354
IPX5D