7.22 System log

Group: syslog
NAME
VALUE
enableremotelog
<boolean>
serverip
<IP address>
serverport
514,
1025~65535
level
0~7
setparamlevel
0~2
7.23 UART control
Group: uart (capability.nuart > 0)
NAME
ptzdrivers_i<0~19,
127>_name
ptzdrivers_i<0~19,
127>_location
enablehttptunnel
Group: uart_i<0~(n-1)> n is uart port count (capability.nuart > 0)
DEFAULT
0
<blank>
514
6
0
VALUE
DEFAULT
string[40]
<blank>
string[128]
<blank>
<boolean>
0
SECURITY
DESCRIPTION
(get/set)
6/6
Enable remote log.
6/6
Log server IP address.
6/6
Server port used for log.
6/6
Levels used to distinguish the
importance of the information:
0: LOG_EMERG
1: LOG_ALERT
2: LOG_CRIT
3: LOG_ERR
4: LOG_WARNING
5: LOG_NOTICE
6: LOG_INFO
7: LOG_DEBUG
6/6
Show log of parameter setting.
0: disable
1: Show log of parameter setting
set from external.
2. Show log of parameter setting
set from external and internal.
SECURITY
DESCRIPTION
(get/set)
1/4
Name of the PTZ driver.
1/4
Full path of the PTZ driver.
1/4
Enable HTTP tunnel channel to
control UART.
VIVOTEK