TEMPERATURE
ADJUSTMENT
2
&
CONTROL
VACATION
3
MODE 1
45
1) TEMP. CONTROL BUTTON
• TEMP. CONTROL : When TEMP CONTROL button is pressed, the led lamps
LOW, MID, HIGH, VAC, SUPER COOL, LOW will be on in sequence.
TEMP. will be set if the button doesn't get pressed again for 5 seconds.
kFORCED DEFROST : will be start when this button pushed for over 5 seconds
continuously.
lSHORT CIRCUIT OPERATION : will be started and stopped when this button
pushed over 30 times.
2) TEMPERATURE CONTROL
•COMP will be controlled by the on/off condition of each mode.
kSTEP DIFF of ROOM R : 1.5 deg
lOFF point of ROOM R : 0°C
mON/OFF DIFF of ROOM R :
DEFAULT MODE
ENERGY CONSUMPTION MODE : 5
TEMP
8.0-
8.0-
3.0-
3.0-
STEP DIFF
(1.5deg)
1 1
3) FORCED DEFROST
• Defrost mode will be Started independent of the cycle.
k The flow is same as the general defrost mode flow.
4) SHORT CIRCUIT OPERATION
•COMP & FAN will be on independent of the operation condition.
kThe time limit of SHORT CIRCUIT OPERATION : 60 hrs
Press TEMP. CONTROL button and make 1LED lamp on.(Case:
ENERGY CONSUMPTION MODE)
ON POINT : 8.0°C
OFF POINT : 3.0°C
: 4 deg
deg
6.5-
6.5-
5.0-
5.0-
1.5-
1.5-
0.0-
0.0-
STEP DIFF
STEP DIFF
(1.5deg)
(1.5deg)
2
3
3.5-
3.5-
ON -
2.0-
2.0-
OFF -
-1.5-
-1.5-
-3.0-
-3.0-
STEP DIFF
(1.5deg)
4
5
DEFAULT MODE &