Warnings And Error Messages - HITEC X1 AC Plus Instruction Manual

Hitec ac/dc input, professional balance charger/discharger
Table of Contents

Advertisement

Warnings and Error Messages

REVERSE POLARITY
CONNECTION BREAK
SHORT ERR
short is found in one of the leads or plugs you may have a faulty battery, which
should not be charged any further.
INPUT VOL ERR
from a 100 to 240AC outlet or from an 11-18V DC power source.
VOL SELECT ERR
BREAK DOWN
BATTERY CHECK
LOW VOLTAGE
BATTERY CHECK
HIGH VOLTAGE
BATTERY VOLTAGE
CELL LOW VOL
BATTERY VOLTAGE
CELL HIGH VOL
BATTERY VOL ERR
CELL CONNECT
34
Reverse Polarity
The battery/charger connections (red/black) are reversed.
Connection Break
The battery connection has been diconnected.
Short Circuit
There is a short circuit in one of the leads or plugs. If no
Input Voltage Error
The input voltage is incorrect. The X1 is can draw power
Input Selection Error
The voltage of the battery pack has been selected
incorrectly.
Break Down
The charger has malfunctioned. Contact Customer
Service at 858.748.1767 or at service@hitecrcd.com.
Battery Check - Low Voltage
The charging voltage is lower than what was input.
Battery Check - High Voltage
The charging voltage is higher than what was input.
Battery Voltage - Low Cell Voltage
Voltage of one cell in the battery pack is too low. Check
the voltage of each cell.
Battery Voltage - Low Cell Voltage
The voltage of one cell in the battery pack is too high.
Check the voltage of each cell.
Battery Voltage - Cell Connection Error
No balance adaptor is detected while charging in bal-
ance mode.