Installation
Instructions
(cont'd)
USE WITHOUT
POWER
CORD
(cont'd)
3. A standard
½" conduit
opening
has been made in the water
beater junction
box for the conduit
connection.
4. Use wire nuts and connect
the power supply
wiring to the
wires inside the water heater's junction
box.
5. The water
heater
must
be electrically
"grounded"
by the
installer.
A green ground
screw has been provided
on the
water heater's junction
box. Connect ground wire to this
location. For complete grounding details and all allowable
exceptions, refer to local codes or in the absence of local
codes, with the latest edition of the National Electrical Code,
ANSI/NFPA 70.
6. Replace
the
wiring
junction
cover
using
the
screw
provided.
WIRING
DIAGRAM
o_o_
SWITCH
OAS
P_E_RE
SW_rCH
I_OVGAS
SOLEN_O
HI_M T
NO
REswlTCH
INOI_TOR UGHT I_OV
O
NC
A_RP_ESSUnE
_WlrCH
HOT
_EUTR_
_JTE
...... 11
w.,,0
.....
t
t20V _AS
SOLENOIO
!l
ir
oAs
P_ESSUnE
S_TCH
__ /
Venting
_,WARNING
To insureproperventingof thisgas.fired water heater,the cor-
rect vent pipe diameter must be utilized. Any additionsof
other gas appliances on vent with this water heater will
adversely affectthe operationofthe water heater,
The combustion and ventilation air flow must not be obstructed.
_,WARNING
3"
diameter t
The vent pipe from the water heater must be I/4 inch per/
PVC schedule40 pipe and must slopeupward
linear foot.
J
All vent gases must be completely vented to the outdoors of the
structure (dwelling).
_,WARNING
The water heater with draft hood installedmust be properlyI
vented to a chimneywhichterminatesoutdoors.Never oper-
ate the water heaterunless it isventedto the outdoorsandhas
adequateair supply to avoidrisks of improperoperation,explo-
sionor asphyxiation.
_,WARNING
Obstructedor deterioratedvent systems may presenta serious
healthrisk or asphyx ation.
15
•,WARNING
I
Failureto haverequired clearances betweenwater heater and
combustible materialwill result in a fire hazard.
I