Installation
Instructions
(cont'd)
2. The convertible element is located behind the lower access
panel of the water heater, Remove the two screws securing
the access panel, and remove panel,
5, Remove the screws from terminal 2 of the element, and move
the looped end of the wire aside.
3, Remove the insulation block to expose the opening,_
6, The buss bar is labeled 5500 W. Place the buss bar over termi-
nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3,
S5OOW
4o Lower
Element:
Lift out the tab as shown
to unclip
the
terminal
cover from the thermostat,
The terminal
cover can
now be removed from the thermostat
TERMINAL
COVER
pLASTIC
TABS
ON
CUPPED
TO THER-
/BOTH
SIDF_
OF
H OSTAT AT THIS
TERMINAL
COVER
POINT
HOLD
IT tN
PLACE_
LOWER
THERHO_TAT
JACKET
7, The wire removed from terminal 2 has a looped end, It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw°
8. Tighten
terminals
2 and 3 to ensure proper
electrical
connection,
11