Download Print this page
York TM9M Technical Manual
York TM9M Technical Manual

York TM9M Technical Manual

Tm9m series 97% afue modulating psc residential gas furnaces multi-position

Advertisement

Quick Links

TECHNICAL GUIDE
97% AFUE MODULATING PSC
RESIDENTIAL GAS FURNACES
MULTI-POSITION
MODELS: TM9M
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residential
applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closing for new
home construction.
See Limited Warranty certificate in Users Information Manual for details.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and venr piping.
FEATURES
Modulating heating operation includes:
- Modulating gas valve, inducer and circulating blower
- Modulating operation from 100% to 35% input in 100%
increments with nearly constant temperature rise.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low
unit
amp
requirement
application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger
with stainless steel tube/aluminum fin secondary heat
exchanger for outstanding efficiency.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic
performance.
1/4 turn knobs provided for easy independent door
removal.
Internal condensate trap design (patent pending) provides
condensate management options and is self priming to
prevent nuisance problems.
4 speed, direct drive, PSC motor.
563717-YTG-C-0713
for
easy
replacement

Advertisement

loading

Summary of Contents for York TM9M

  • Page 1 Movable duct connector flanges for application flexibility. are subject to change without notice. • Quiet inducer operation, burner, and blower operation. Visit us on the web at www.york.com • Inducer rotates for easy conversion of venting options. Additional rating information can be found at •...
  • Page 2 563717-YTG-C-0713 RIGHT SIDE LEFT SIDE FRONT Combustion Air Inlet Combustion Air Inlet Condensate Drain Gas Pipe Gas Pipe Condensate Drain (Downflow) Entry Entry (Downflow) 2” Vent Electrical Electrical Connection Entry 2” Vent Entry Outlet Connection Condensate Outlet Drain Condensate 23” Drain Thermostat Wiring...
  • Page 3 563717-YTG-C-0713 FILTER PERFORMANCE Concentric Vent Termination - For use through rooftop, side- wall. Allows combustion air to enter and exhaust to exit through The airflow capacity data published in the “Blower Perfor- single common hole. Eliminates unslightly elbows for a cleaner mance”...
  • Page 4 4. Airflow through across motor side (right side) may be slightly less than the data shown above. Subject to change without notice. Published in U.S.A. 563717-YTG-C-0713 Copyright © 2013 by Johnson Controls, Inc. All rights reserved. Supersedes: 563717-YTG-B-0512 York International Corp. 5005 York Drive Norman, OK 73069...

This manual is also suitable for: