GUIDE
96% TWO STAGE VARIABLE SPEED
ECM GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: TM9V
NATURAL GAS
40 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year heat exchanger warranty on commercial applica-
tions.
Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for
replacement or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and venr piping.
FEATURES
Two stage heating operation includes two stage gas valve,
two stage inducer operation and variable speed ECM
blower operation. Adjustable delay timer allows two stage
operation with a single stage thermostat.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
ECM variable speed drive for cooling SEER enhancement,
improved comfort with optional airflow delay profiles, and
continuous fan options for IAQ performance.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement applica-
tion.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger
with stainless steel tube/aluminum fin secondary heat
exchanger for outstanding efficiency.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow for duct-
blaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic
performance.
1/4 turn knobs provided for easy independent door
removal.
Internal condensate trap design (patent pending) provides
condensate management options and is self priming to
prevent nuisance problems.
Protection included from air intake, exhaust vent or con-
densate blockage.
Venting applications maybe installed as either 2 pipe
sealed combustion or single pipe vent using indoor com-
bustion air.
700709-BTG-B-0512

Advertisement

loading

Summary of Contents for York TM9V080B12MP11

  • Page 1 Fully supported blower assembly for easy access and are subject to change without notice. removal of blower. Visit us on the web at www.york.com • External air filters used for maximum flexibility in meeting Additional rating information can be found at customers IAQ needs.
  • Page 2 Nominal Cabinet Dimensions (Inches) Cabinet Operating Weights Model Size CFM (m /min) TM9V040A10MP11 1000 14-1/2 13-3/8 11-3/4 TM9V060B12MP11 1200 17-1/2 16-3/8 13-1/4 TM9V080B12MP11 1200 17-1/2 16-3/8 13-1/4 TM9V080C16MP11 1600 19-7/8 16-1/2 TM9V100C16MP11 1600 19-7/8 18-1/4 TM9V100C20MP11 2000 19-7/8 18-1/4 TM9V120D20MP11...
  • Page 3 700709-BTG-B-0512 FILTER PERFORMANCE Concentric Vent Termination - For use through rooftop, side- wall. Allows combustion air to enter and exhaust to exit through The airflow capacity data published in the “Blower Perfor- single common hole. Eliminates unslightly elbows for a cleaner mance”...
  • Page 4 Consult the instructions for the electronic air cleaner for further details. * The ADJ “D” tap should not be used. Subject to change without notice. Published in U.S.A. 700709-BTG-B-0512 Copyright © 2012 by Johnson Controls, Inc. All rights reserved. Supersedes: 700709-BTG-A-0811 York International Corp. 5005 York Drive Norman, OK 73069...

This manual is also suitable for:

Tm9v080c16mp11Tm9v100c16mp11Tm9v100c20mp11Tm9v120d20mp11Tm9v060b12mp11Tm9v040a10mp11