1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is
to be performed.
A.
This appliance has a pilot which must be lighted by
a piezo ignitor.
When lighting the pilot, follow these instructions
exactly.
B.
BEFORE LIGHTING smell all around the appliance
areas for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
1. STOP! Read the safety information above on this label.
2. Set the thermostat to lowest setting.
3. Open lower door.
4. Turn off all electric power to the appliance.
5. Push in gas control knob slightly and turn
clockwise
to "OFF".
Gas Control Knob
Shown in "OFF"
Position
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless
knob is pushed in slightly. Do not force.
6. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP!
Follow "B" in the safety information above this label. If you
don't smell gas, go to the next step.
7. Find pilot. The pilot is between the two ceramic logs,
behind the burner.
USSC
TURNING GAS OFF TO APPLIANCE
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.

LIGHTING INSTRUCTIONS

S
it
E
A
Piezo Button
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
3. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
•If you cannot reach your gas supplier, call the fire
department.
C.
Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, don't try to repair it, call a qualified service
technician. Force or attempted repair may result in a fire
or explosion.
D.
Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
Ceramic Logs
8. Turn knob on gas control counterclockwise
"PILOT".
9. Push in control knob all the way and hold in. Immediately
light the pilot by pushing in on the piezo button. Continue
to hold the control knob in for about one (1) minute after,
the pilot is lit. Release knob and it will pop back up.
Pilot should remain lit. If it goes out, repeat steps 5
through 9.
If the knob does not pop up when released, stop and immediately
call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control
knob to "OFF" and call your service technician or gas supplier.
10. Turn gas control knob counterclockwise
11. Turn on all electric power to the appliance.
12. Set thermostat to desired setting.
13. Close lower door.
Pilot
Burner
to
to "ON"