Self-Diagnostic Circuit; Vertical Deflection Stopped; Vertical Deflection Overcurrent; White Balance Failure - Sony Trinitron KV-XF29M97 Service Manual

Bg-3s chassis trinitron color tv
Table of Contents

Advertisement

6.

SELF-DIAGNOSTIC CIRCUIT

[+B overcurrent ªOCPº]
[Vertical deflection stopped]
[Vertical deflection overcurrent]
[White balance failure]
http://cxema.ru
IC301
Y/CHROMA JUNGLE
FROM
21
IK-IN
CRT
FROM
MP/
[+B] Q604 C
18
PROTECT
SDA
[V] Q509/507
Occurs when an overcurrent on the +B(135) line is detected by Q604. If Q604 go to ON
and the voltage to pin 18 of IC301 should go down when V.SYNC is more than seven
verticals in a period, the unit will automatically turn off.
Occurs when an absence of the vertical deflection pulse is detected by Q509 and IC001
shut down the power supply.
Occurs when an overcurrent on V drive line is detected by Q507. Power supply will be
shut down when detect this by IC001.
If the RGB levels* do not balance or become low level within 5 seconds, this error will be
detected by IC301. TV will stay on, but there will be no picture.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
IC001
SYSTEM
IO-8DAT
45
O-LED
51
35
46
IO-SDAT
– 7 –
KV-XF29M97/XF29M67
IC003
MEMORY
5
B-DAT
RM-953