Keating Of Chicago Filter System Thermostat Service Instructions

Keating of chicago inc.thermostat service instructions

Advertisement

Quick Links

S E R V I C E I N S T R U C T I O N S
www.keatingofchicago.com
A. To Replace "O" Rings (refer to exploded view)
1.
Remove 4 bolts #8. The housing will come apart. Replace "O" rings making sure the
"O" ring is in the groove in the housing.
B. To Replace Lip Seal
1.
The lip seal is located in the bracket Item #1. Using a flat blade screwdriver, knock
out the old lip seal. CAUTION: Be careful not to damage the bearings.
2.
Using an Arbor Press, press the new lip seal into the bracket #1.
3.
Replace all sections of the pump making sure none of the "O" rings are pinched
between the sections.
4.
Tighten down the 4 bolts by alternating between them.
ITEM DESCRIPTION
1
2
3
4
6
7
8
VIKING REBUILT PUMP KIT
Typical SG-07
Exploded View
Bracket, lipseal & bearing section
Match ground casing & (2) gears, driver & driven shafts
Separation plate & bearing assembly
Head and alignment sleeve assembly
Lipseal
O-ring
Assembly capscrews
1-800-KEATING
VkngRbltPmp
7/98