Summary of Contents for Natural Choice ION pure refreshment

  • Page 1 ECHNICAL ERVICE ANUAL NCC7222-07 R2- 111207...
  • Page 2: Opening The Appliance

    Opening the Appliance • CAUTION: Unplug from electrical outlet before servicing • IMPORTANT: Torx 20 screwdriver required Remove Top Panel Remove Left Side Panel Remove Faucet Cover • Loosen 2 screws at top, rear • Remove 3 screws left side •...
  • Page 3: Control Board

    Major Components Service View Ice Bank Power Supply Touch Panel Sleep Mode Sensor LED1 LED2 LED/ SleepMode Sensor Control Board Faucet Filter Access Compressor Front Panel Assembly Hot Tank NCC7222-07 R2- 111207...
  • Page 4 Evaporator InstaChill ™ Cooling System Water Coil • Uses a 20’ length of 1/4” OD Water Coil inside a Tank (called Ice Bank) filled with water and ice. Ice Bank • No reservoir of drinking water. • 3” thick slab of ice is formed on left side of Ice Bank.
  • Page 5 InstaChill ™ Cooling System Model 901 Model 902 Cold and Ambient Cold and Hot Inlet to Ice Bank Inlet to Ice from Filter Bank from Fill Valve Stainless Steel Water Coil Tee to Hot or Ambient Alternate Location Water Valve for Cold Thermistor Cold Thermistor Evaporator...
  • Page 6 InstaChill ™ Cooling System Model 903 Model 904 Model 905 Cold and Sparkling Cold, Hot and Sparkling Cold, Hot and Ambient NCC7222-07 R2- 111207...
  • Page 7: Dispensing Valves

    Water Pathway Inlet to Ice Bank Inlet to Water from Fill Valve Coil from Filter The Water pathway inside the ION is sealed and pressurized in 1/4” OD tubing (about 23’ total inside the appliance). Tap Water supply tubing connects directly at the rear of the appliance to an Inlet Valve.
  • Page 8 RapidHot ™ Water System FUNCTION – Water from Filter enters Ice Bank Assembly, Filtered Water but is diverted with Tee fitting and bypasses the Ice Bank Water Coil. Outlet Tube Inlet to Hot Tank Blue Water Tubing from Ice Bank Assembly travels to Hot Hot Valve Vent Tube Water Valve, attached to Hot Tank.
  • Page 9 ION Software Revision Level Date Notes/Changes July 30, 2006 Production Release. SleepMode default is OFF Filter Settings at 1,500 gallons and 12 months August 13, 2006 Changed Compressor cycle times October 27, 2006 Increased Hot Temperature settings December 10, 2006 Minor coding change April 15, 2007 Changed Ice Bank Pump ON time from 30 seconds to 60 seconds...
  • Page 10: Wiring Diagram

    AC LINE VOLTAGE IN GROUND INLET PIN 3 NEUTRAL PIN 2 - WHITE VALVE PIN 1 + RED 24 Volt DC #6518 Components Natural Choice Corporation Rockford, IL 61109 phone 815.874.4444 www.naturalchoicewater.com All Rights Reserved, Natural Choice Corp. NCC7222-07 R2- 111207...
  • Page 11: Troubleshooting Guide

    Troubleshooting Guide Problem: Water Dispenses from Cold or Sparkling Valve, but Water not Cold page 11 No Water Dispenses From Cold or Sparkling Valve page 12 Water dispenses from Hot Valve, but water not Hot page 13 No Water dispenses from Hot Valve page 14 Low or No Water Flow page 15...
  • Page 12: Troubleshooting Chart

    Troubleshooting Chart Problem: Water Dispenses from Cold or Sparkling Valve, but Water not Cold Cause Action 1. ION has been in SleepMode (with compressor off) for 1. Allow ice to build over 3-4 hour time period. Optionally, weekend or long holiday. program SleepMode to be OFF (Ice Bank to be maintained 24 hours per day).
  • Page 13 Troubleshooting Guide Problem: No Water Dispenses From Cold or Sparkling Valve IMPORTANT – Do you hear both Inlet Valve and Cold Valve “double-click” when opening and closing? Inlet Valve must open to allow water into ION. Dispensing Valve then allows water out of appliance. Therefore, when dispensing water, you will hear two valves clicking open and closed in quick succession.
  • Page 14 Troubleshooting Guide Problem: Water dispenses from Hot Valve, but water not Hot Cause Action 1. ON/OFF switch at back of ION 1. Turn to ON position. 2. Wiring and connectors at Control Board 2. Check for continuity (not voltage) through the hot tank connector and wiring harness at Control Board (with ION unplugged and Switch in ON position).
  • Page 15 Troubleshooting Guide Problem: No Water dispenses from Hot Valve Cause Action 1. Are customers pressing BOTH Hot and Safety button 1. Refer to Instruction Label inside filter door of appliance at same time? and notify customer. 2. Do you hear both Inlet and Dispensing Valve clicking open and closed?.
  • Page 16 Troubleshooting Guide Problem: Low or No Water Flow IMPORTANT – Keep in mind that inside the ION, there is a 1 micron carbon filter and 23’ of 1/4” tubing (the Water Coil is 20’ in length). Plan ahead for adequate water pressure and flow rate into the ION. Cause Action 1.
  • Page 17 Troubleshooting Guide Problem: Blue LED not ON IMPORTANT – SleepMode is an energy saving feature that is programmed into the Control Board. A photo sensor behind the LED3 on Front Panel allows software to turn the compressor OFF when room is dark. Check the location carefully…...
  • Page 18 Troubleshooting Guide Problem: Blinking RED lights (both together, not alternating) IMPORTANT – Ice Bank automatically fills by using a Level Sensor. To prevent endless water flow from failed Level Sensor, software only allows the Ice Bank to fill for 5 minutes on STARTUP. Once the ION has passed STARTUP, the Ice Bank is limited to a fill time of 2 minutes.
  • Page 19 Troubleshooting Guide Problem: Steady Orange lights (never goes to blinking Orange lights) IMPORTANT – on software rev level prior to L (Sept. 2007), a hot or cold sensor unplugged (or not completely connected) will cause this condition. During shipping, the sensor connections can become unstable and may require careful removal (straight back) and reinsertion onto the Control Board (see wiring diagram).
  • Page 20 Troubleshooting Guide Problem: Water Leak IMPORTANT – the ION uses an Inlet Valve to allow water to enter the appliance. Only when the customer presses Touch Panel to dispense water – or when Ice Bank automatically fills – does the Inlet Valve open to allow water to enter the appliance.
  • Page 21 Troubleshooting Guide Problem: Steady RED lights – Filter Change required. When pressing Filter Reset button, does not reset RED lights to GREEN. IMPORTANT – When changing filters, ALWAYS reset the filter monitor (time and gallons) to zero by pressing the Filter Reset button until you hear a beep (about 6 seconds).
  • Page 22: Frame Assembly

    Frame Assembly NCC7222-07 R2- 111207...
  • Page 23 Display Valve Assembly (Models 903,904 only) (for Models 903, 904 only) NCC7222-07 R2- 111207...
  • Page 24 Filter Manifold Assembly NCC7222-07 R2- 111207...
  • Page 25: Front Panel Assembly

    Front Panel Assembly NCC7222-07 R2- 111207...
  • Page 26 Dispensing Assembly – 901 NCC7222-07 R2- 111207...
  • Page 27 Dispensing Assembly – 902 NCC7222-07 R2- 111207...
  • Page 28 Dispensing Assembly – 903 NCC7222-07 R2- 111207...
  • Page 29 Dispensing Assembly – 904 NCC7222-07 R2- 111207...
  • Page 30 Ice Bank Assembly NCC7222-07 R2- 111207...
  • Page 31: Final Assembly

    Final Assembly NCC7222-07 R2- 111207...

Table of Contents