10

sPeciFicaTions

accessories
Binocular tube
- with fixed angle
3 different selection options
- variable
3 different selection options

Handles

2 variants: sterilizable/disinfectable or disinfectable
Rotary knobs
sterilizable

Protective glass

sterilizable
orange filter
external uv light filter up to 530 nm for illumination and
observation

ergoWedge

5°- to 25°-angle for binocular tubes with fixed angle

ergonoptic dent

with 52° swivel angle, for binocular tubes variable
from 0° to 180°
Remote control
iR remote control for the integrated video camera
counterweight
Weight for balancing the optics carrier
Beam splitter
50/50 % and 70/30 %
stereo adapter
spacer for assembly of the beam splitter

eyepieces

8.33×, 10×, 10× with crosshair graticule, 12.5×
video accessories
Leica M320 FULL HD Video & Photo Camera
integrated (optional) Full
1920×1080 px video resolution and 10 MB photo resolution
Hd video camera
Functions
Playback function for video and photo and thumbnail view
storage
video and photo on sd card, video optionally also on
external recording system
video signal
available in HdMi and analog (Pal/nTsc selectable)
video/photo control
iR remote control and two hard keys on camera body,
all camera settings with on screen menu
Leica M320 iVa integrated Video adapter

adapter

integrated (optional) video adapter for attachment of
external c-mount cameras
length of optics
Focal length of optics f=55 mm
ambient conditions
use
+10 °c to +40 °c
+50 °F to +104 °F
30 % to 75 % relative humidity
500 mbar to 1060 mbar air pressure
storage
–30 °c to +70 °c
–22 °F to +158 °F
10 % to 100 % relative humidity
500 mbar to 1060 mbar atmospheric pressure
Transport
–30 °c to +70 °c
–22 °F to +158 °F
10 % to 100 % relative humidity
500 mbar to 1060 mbar atmospheric pressure
standards fulfilled
- Medical devices directive 93/42/eec including amendments.
CE conformity:
- classification: class i, in compliance with appendix ix, Rule 1, and
Rule 12 of the directive.
- Medical electrical equipment, part 1: General requirements for safety
iec/60601-1; en/60601-1; ul60601-1; can/csa-c22.2 no. 601.1-M90.
- electromagnetic compatibility iec/60601-1-2; en/60601-1-2.
- according to sqs certificate, leica Microsystems (schweiz) aG,
Medical division has a management system which corresponds to the
requirements of the international standards iso/9001, iso/13485 and
iso/14001 for quality management, quality assurance and environ-
mental management.
54