ETUP

Unpacking

The MAC 250 Krypton comes with:
• MSD 250/2 lamp (not installed)
• 3-meter, 3-wire IEC power cable
• user manual
• 1/4-turn clamp mounting bracket
• 5-meter, 3-pin shielded XLR control cable
The packing material is carefully designed to protect the fixture during shipment - always use it or a custom
flight case to transport the fixture.

Lamp installation

A lamp must be installed prior to initial operation.
C O M P A T I B L E L A M P S
A Philips MSD 250/2 lamp is included. The MAC 250 Krypton lamp options are shown in the table below.
Installing any other lamp may damage the fixture.
I N S T A L L I N G A L A M P
Danger!
Intense heat. Avoid contact by persons and materials. The exterior of the fixture can get
very hot - up to 120° C (248° F). When replacing the lamp, disconnect the fixture from AC
power and allow it to cool for at least 45 minutes before proceeding. Wear safety goggles
to protect your eyes.
1 Locate the lamp access cover at the back of the fixture head and remove the Phillips screws.
6
Lamp
Average life
Osram HSD 250/78
3000 hr
Philips MSD 250/2
2000 hr
GE CSD 250/2
2000 hr
Table 1: Lamp comparison