Download Print this page

Advertisement

Quick Links

Welcome to
Welcome to
Security and
Peace of Mind

Advertisement

loading

Summary of Contents for Meridian Euro

  • Page 1 Welcome to Welcome to Security and Peace of Mind...
  • Page 2 THIS INFORMATION IS FOR USE BY THE INSTALLER ONLY To simplify operation for the user and to avoid unnecessary confusion, the Meridian User Manual can be made up to include only relevant information. Remove the pages you do not require from the binder supplied Sections Content ✔...
  • Page 3 Walk Testing Detectors Testing your Sounders Manager Menu Exit Service Information Note; The specification of Euro Meridian may change from model to model and some facilities in the manual may not be available. Check with your installer for full details.
  • Page 4 You've Made the Right Choice Using your Meridian Alarm System just couldn't be easier! This is the Keypad from where you control your Alarm System.
  • Page 5 The Meridian Keypad The display gives you any MAINS FAIL important messages. The 10 digit numeric keypad is where you use your PIN code. MERIDIAN TIME: The A B C D keys help simplify use, and will light to highlight your choice of security cover, or flash if there is a problem.
  • Page 6 Other Setting Points All setting points (Meridian keypads or Tag Readers) have lamps to clearly indicate what is happening. The ‘Power’ lamp will flash if the mains supply fails. The ‘Alarm’ lamp will flash if an alarm occurs. The ‘Tamper’ lamp will flash if Meridian’s wiring or equipment is...
  • Page 7 Using Tag Meridian's High Security Proximity Tag can be used to set or unset your Alarm System with the minimum of fuss or complexity. The Tag contains NO batteries and is completely maintenance free. Just touch the Tag to the logo to use.
  • Page 8 Using the Keypad With Your PIN Code...
  • Page 9 Security Checks Before you switch Meridian on You must ensure all doors and windows are securely closed and any pets or people are excluded from areas protected by movement sensors. Close Windows Close Doors Exclude Pets and people...
  • Page 10 Leave by the agreed exit route. SETTING Close and lock the final exit door. OFFICE Finally, press the 'Push to Set' button (if fitted) that is mounted externally by the final exit door. Exit tone will cease. Meridian is now SET.
  • Page 11 Faults when you switch Meridian on If when you key in your PIN Code or present your Tag a warning tone sounds and the fault lamp comes on, a message will show the nature of the problem. If appropriate an ‘ABCD’ key will...
  • Page 12 Return to the keypad and note the message on the display. EXIT VIA HALLWAY Switch Meridian off with your PIN code, or Tag. Close the open door Now commence the setting procedure again (see B2)
  • Page 13 Keypad. ENTRY TIME [20] Entry tone will be sounding. "Beep - Beep - Beep - - - " ENTRY TIME [10] Key in your PIN code,or present your Tag. Entry tone will cease. Meridian is now UNSET.
  • Page 14 Intelligent Setting Part - Setting Meridian If you wish to set Meridian and stay in the building (eg set the alarm at night) Meridian's intelligent operating system will realise what you require and set only part of the system. You will NOT need to press a 'Push-to-Set' button if you set only part of the system.
  • Page 15 Intelligent Setting Staying in the building To Part Set Meridian go to the Keypad and enter your PIN code or present your Tag. The appropriate ‘ABCD’ keys will light Exit tone will start. Leave the protected area and retire to the un-protected area (eg Upstairs).
  • Page 16: Pin Code

    When Problems Arise Just Key In Your PIN Code Present Your Tag...
  • Page 17 The Alarm will stop sounding. The display will indicate ALARM SILENCED LOW VOLTS the problem and the appropriate lamp will light. Press the 'YES' key. Meridian will advise you on the CALL ENGINEER action to take if needs be. LOW VOLTS...
  • Page 18 Engineer Reset When Meridian has been reset after an alarm a random 5-digit code may be displayed, along ENGINEER RESET REQUIRED 21055 with the message "RESET REQUIRED". Normally it is then necessary for an engineer, from your installing company, to check the installation and reset the system for further use.
  • Page 19 Setting Individual Areas...
  • Page 20 Sometimes your security needs MERIDIAN will be a little more complex and TIME: you will need to use Meridian's A B C D keys. Your Installer can also give names to all four of the A B C D areas, so that you can easily identify them.
  • Page 21 Codes with Flexi-Set For greater flexibility in setting parts of your Meridian system, you can make a choice at the Keypad Key in your PIN code or present your Tag SET AREAS [ABCD] If you do not wish to set all the...
  • Page 22 When Partially Set MERIDIAN TIME: When Meridian has some areas already set and you wish to Set or Unset any areas Key in your PIN code or present your Tag Unset Areas? UNSET AREAS? (Press 'NO' To move to the next Menu)
  • Page 23 More Advanced Functions...
  • Page 24 The 'Chime' Facility The 'C' key can be used to select the 'Chime' facility while the system is Unset MERIDIAN TIME: For example, you may wish to be alerted if someone enters through a particular door during the day. Simply press the 'C' key.
  • Page 25 To omit the window Press ‘YES’ LEAVE OPEN? BEDRM WINDOW (or ‘NO’ if you don’t!) Meridian will then set as normal. The window will be omitted for this one arming period only. Note. Only already open doors or windows can be omitted in this way.
  • Page 26 If it has been accepted it will be displayed on the screen. Repeat for any other zones that need to be omitted. After 10 seconds Meridian will begin to Set. These zones will be omitted for this one period only.
  • Page 27 Keypad Personal Attack If you ever need to summon personal assistance in an emergency, Meridian allows you to do so. MERIDIAN TIME: Simply Press the '1' and '7' keys at the same time. This may also send a signal to the Alarm Receiving Centre.
  • Page 28: Manager Menu

    Manager Menu To enter Manager Menu simply key in your Manager Code. Your system must be fully disarmed to enter Manager Menu...
  • Page 29 Manager Menu MERIDIAN TIME: The Manager Menu is accessed by keying in your Manager PIN Code. You then have a choice of: Set System? Omit Zones? Set Date and Time? Change Codes? Review History? Print History? Walk Test? Siren Test?
  • Page 30 The ‘Unset’ lamp will light The first Menu choice asks you if you wish to 'SET SYSTEM?’ SET SYSTEM? If you wish to set Meridian press ‘YES’. But if you wish to move on to other Manager Menu items press ‘NO’.
  • Page 31 (Press 'NO' To move to the next Menu) Some of your doors may be rarely used. Opening them, even with OMIT ZONES Meridian Unset, may cause an alarm. If you need to open these doors you can omit them from the system as shown below.
  • Page 32 Enter Day (1-31) [ 12 ] Press'YES' Enter Hours HOURS (0-23) [ 10 ] Press 'YES' Enter Minutes MINUTES (0-59) [ 17 ] Press 'YES' To go to the next Menu. Press 'NO' again. Euro Meridian is fully ‘Year 2000’ compliant...
  • Page 33: User Codes

    User codes Warning: Do Not Store this in The Manual, Put in a Secure Place Photocopy this page if you have more users Name Code Type Areas Attributes Flexi Access RDR 1234 Manager ABCD SET/UN 1 2 8...
  • Page 34 Changing or adding new PIN Codes/Tags Press 'YES' CHANGE CODES? (Press 'NO' To move to the next Menu). Press 'YES' CHANGE USER (Press 'NO' To programme the Master CODES? Manager Code). Turn to the next page to continue to programme user codes. Press 'YES' MASTER MANAGER (Press 'NO' To move to the next Menu).
  • Page 35 Changing or adding new PIN Codes/Tags Meridian identifies each of the 20 Users by a different ‘User USER NUMBER Number’. eg. 'John' would be user [ 02 ] 01 - 'Jane' would be user 02 etc. Now key in the ‘User Number’...
  • Page 36 Changing or adding new PIN Codes/Tags Choose the level of authority the code-holder is allowed. User - cannot use Manager Menu Manager - can use Manager Menu USER TYPE (USER) (Use 'B & D' keys to make your choice). Press 'YES' Using the A B C D keys, choose the USER AREAS: areas you wish to be controlled by...
  • Page 37 Changing or adding new Pin codes/Tags Flexi-Set gives you the opportunity to choose the areas you require to FLEXI-SET set when you use your PIN code or Tag. If you do not choose Flexi-Set your Code/Tag will simply set the areas FLEXI-SET assigned without offering you the opportunity to choose.
  • Page 38 Changing or adding new Pin codes/Tags If you do not have Access Control or Wards, go to F12 Press ‘YES’ ASSIGN CODES TO READERS? (Press 'NO' To move to the next Menu) To assign a Tag to Access Control WARDS ACCESS[ - - ] Readers, or a Ward Reader Enter the Reader Numbers required.
  • Page 39 Changing or adding new PIN Codes/Tags Where available, using the numeric keys you can enter a user name. USER NAME 1=ABCD 2=EFGH 3=IJKL JOHN SMITH 4=MNOP 5=QRST 6=UVWX 7=YZ, - 8= ./01 9= 2345 0= 6789 The ABCD keys on the keypad are used as follows;...
  • Page 40 Review History Log Press'YES' REVIEW LOG? (Press 'NO' To move to the next Menu) USER LOG Press'YES' To advance through the Logs. AN EVENT DATE AND TIME: Press 'YES' For added information REVIEW LOG? Press ‘C’ To stop Review. Press 'NO' To move to the next Menu, press 'NO' again.
  • Page 41 Print History Log Press'YES' PRINT LOG? (Press 'NO' To move to the next Menu) Select the Log you wish to print PRINT LOG with the ‘B’ and ‘D’ keys. USER [ 0 ] USER LOG ACCESS LOG Press 'YES' if you wish to print events as PRINT ON LINE they happen NONE...
  • Page 42 Check all detectors are working WALK TEST? Press 'YES' (Press 'NO' To move to the next Menu) Choose the area(s) you wish to test by pressing the appropriate ABCD keys Press 'YES' FRONT DOOR All zones to test will scroll in the display.
  • Page 43 Testing your Alarm sounders SIREN TEST? Press 'YES' (Press 'NO' To move to the next Menu) Press 'YES' TESTING SIREN Siren will sound, Strobe will flash. Press 'NO' SIREN TEST? to move to next Menu.
  • Page 44 Menu exit This menu is reserved for your ENGINEER MENU? Service Engineer and cannot be accessed by normal users. Press 'NO' to move to next Menu. To exit from Manager Menu and EXIT MANAGER MENU? return to normal mode. Press 'YES' If you wish to select any of the Manger Menu items again press the 'NO' key until your choice is...
  • Page 45 Service Information We are sure that you will be delighted with your Euro-Meridian Alarm installation. For your personal reference here is a record of the relevant service information Service Company Date of installation Site Reference 24hr Service Number Tel: Keyholders...