Attendant Group Calls - Panasonic DBS576 Section 700 Technical Manual

Feature operation
Hide thumbs Also See for DBS576 Section 700:
Table of Contents

Advertisement

Chapter 5. Key Telephone Features
5. Press a vacant CO key or enter a trunk access code.
6. Dial the phone number.
Hardware Requirements
An SMDR printer or external call accounting system is required to collect account code records.
Related Programming
FF1-0-19: TRS Class for Forced Account Code
FF1-2: Dial Plan
FF3: Forced Account
FF3: Verified Account
FF8-1-04: Verified Account Codes with TRS Class
Considerations
Account codes are not available during conversation recording mode for the Built-In Voice Mail.
Account codes will be cancelled after using CO queuing.
Account Codes interact with TRS as shown in the following table:
Forced or Not Forced
Not Forced
Forced

Attendant Group Calls

CPC-96, CPC-288, and CPC-576 All Versions
Description
You can call the attendant group from any extension by dialing the designated attendant number.
124
Action
Verified or
Non-Verified
Non-Verified
Extension Port Based TRS
Verified
Non-Verified
Verified
DBS 576 (USA), issued January 1999
CO Key LED lights
Dialed phone number displays
TRS Class
No Account Entry
Class
TRS Class for Forced
Account Code
(FF1 0 19 0001)
Section 700 - Operation
Result
Account Entry
Extension Port Based TRS
Class
Account Code Based TRS
Class
Extension Port Based TRS
Class
Account Code Based TRS
Class
576-20-700