Sleep Timer Operation - LG LS-J0761NL Service Manual

(exploded view)
Hide thumbs Also See for LS-J0761NL:
Table of Contents

Advertisement

10. Sleep timer operation

• When the sleep time is reached after [1,2,3,4,5,6,7hr] is input by the remote control during the operation, the
operation of the appliance stops.
• When the appliance is on pause, the sleep timer mode cannot be input.
10.1 Sleep timer operation for cooling cycle
• While in cooling mode operation, 60 min. later since the start of the sleep timer, the setting temperature
increase by 0.5°C. After another 60min. elapse, it increases by 1°C again.
Setting temp. (˚C)
Cooling ON temp.
(Setting temp. +0.5˚C)
Cooling OFF temp.
(Setting temp. -0.5˚C)
10.2 Sleep timer operation for heating cycle
• While in heating mode operation, 60 min. later since the start of the sleep timer, the setting temperature
decrease by 0.5°C. After another 60min. elapse, it decreases by 1°C again.
Setting temp. (˚C)
Heating OFF temp.
(Setting temp. +3.0˚C)
Heating ON temp.
(Setting temp)
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
0.1˚C up
0.5˚C up
Sleep time ( hr )
1
2
0.5˚C down
1.0˚C down
Sleep time ( hr )
1
2
- 22 -