Sensor Temperature Monitoring Function - Toshiba HWS-803XWHM3-E Data Book

Air to water heat pump
Hide thumbs Also See for HWS-803XWHM3-E:
Table of Contents

Advertisement

7. HYDRO UNIT INSTALLATION MANUAL
11
SENSOR TEMPERATURE MONITORING
FUNCTION
The sensor sensing temperature is displayed on the
remote controller.
This function allows you to make sure whether the
sensor is installed properly.
Press the TEST
+ CL
or more.
Select the function code with the TEMP.
buttons.
Press the TEST
button to exit the test mode.
Item
Data name
code
00
Control temperature (Hot water cylinder)
01
Control temperature (Zone1)
02
Control temperature (Zone2)
03
Remote controller sensor temperature
04
Condensed temperature (TC)
06
Water inlet temperature (TWI)
07
Water outlet temperature (TWO)
08
Water heater outlet temperature (THO)
09
Floor inlet temperature (TFI)
0A
Hot water cylinder temperature (TTW)
0B
Mixing valve position
OE
Low pressure (Ps) × 100
Item
Data name
code
60
Heat exchange temperature (TE)
61
Outside air temperature (TO)
62
Discharge temperature (TD)
63
Suction temperature (TS)
65
Heat sink temperature (THS)
6A
Current
6D
Heat exchanger coil temperature (TL)
70
Compressor operation Hz
72
Number of revolutions of outdoor fan (lower)
73
Number of revolutions of outdoor fan (upper)
74
Outdoor PMV position × 1/10
buttons for four seconds
Unit
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
step
MPa
Unit
°C
°C
°C
°C
°C
A
°C
Hz
rpm
rpm
pls
– 124 –
Engineering Data Book
Item
Data name
code
F0
Micro computer energized accumulation time × 100h
F1
Hot water compressor ON accumulation time × 100h
F2
Cooling compressor ON accumulation time
F3
Heating compressor ON accumulation time
Built-in AC pump operation accumulation
F4
time
Hot water cylinder heater operation
F5
accumulation time
F6
Backup heater operation accumulation time
F7
Booster heater operation accumulation time
09
Floor inlet temperature (TFI)
0A
Hot water cylinder temperature (TTW)
0B
Mixing valve position
OE
Low pressure (Ps) × 100
Unit
× 100h
× 100h
× 100h
× 100h
× 100h
× 100h
°C
°C
step
MPa
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents