Heat Capacity Control - Navien CH-180 Operation Manual

Navien gas combination water heater
Hide thumbs Also See for CH-180:
Table of Contents

Advertisement

Combination water heater operation

█ Heat Capacity Control

When the heating capacity is small, the desired heat capacity can be controlled by the
use of the remote controller.
Tap "ON/OFF" to turn off the power of
the remote controller.
Use the center dial to adjust the heat
capacity. (Range 30 ~ 100 %)
With the remote Controller off, press
and hold the "DHW" and "Stand By"
button simultaneously for 3 seconds.
The black cursor should make 1
revolution around the clock and the
heat capacity will be displayed on the
right hand side of the clock.
Press "Program" button to complete
setting. If setting is completed Remote
Controller will return "OFF" state.
23