Download Print this page
Konica Minolta PB-501 Installation Manual
Konica Minolta PB-501 Installation Manual

Konica Minolta PB-501 Installation Manual

Perfect binder

Advertisement

Quick Links

Applied Machine: C6500/C6500P/C6501/C6501P/1050/1050P
COLOR MFP: 65ppm/MFP: 105ppm
For Product Code: 56U*-Z*/ 565*-7*/A03U/A03V/A0U0/A0U2
I. Machine Combination Examples
1050 Series
• PB-501+Machine+PF-701
• PB-501+SD-501+Machine+PF-701
(SD-506)
• PB-501+LS-501+Machine+PF-701
(LS-505)
• PB-501+FD-501+Machine+PF-701
(FD-503)
• PB-501+SD-501+FD-501+Machine+PF-701
(SD-506)+(FD-503)
Note: Case of 1050 series
When PB-501 is installed to 1050 series, be sure
to execute;
• Setting of DIP SW
• Perform a software update (ISW)
• Installation procedure of PB-501 to machine (1050 Series C6500/C6501 Series) /options
PB-501+1050 Series . . . . . . E-4 page
PB-501+SD-501 . . . . . . . . . . E-10 page
PB-501+LS-501 . . . . . . . . . . E-12 page
PB-501+FD-501 . . . . . . . . . . E-14 page
• Common operations after installing PB-501 E-17 page to 19 page
PB-501
INSTALLATION MANUAL
A075IXE002SB
* C6501 (RU-504/SD-506/LS-505/FD-503)
Perfect Binder
C6500 Series
• PB-501+RU-503+Machine+PF-601
• PB-501+SD-501+RU-503+Machine+PF-601
• PB-501+LS-501+RU-503+Machine+PF-601
• PB-501+FD-501+RU-503+Machine+PF-601
• PB-501+SD-501+FD-501+RU-503+Machine
+PF-601
C6501 Series
• PB-501+RU-504+Machine+PF-601
• PB-501+SD-506+RU-504+Machine+PF-601
• PB-501+LS-505+RU-504+Machine+PF-601
• PB-501+FD-503+RU-504+Machine+PF-601
• PB-501+SD-506+FD-503+RU-504+Machine
+PF-601
PB-501+RU-503+C6500(C6501 Series) . . E-7 page
PB-501+SD-501+RU-503 . . . . . . . . . . . . . . E-10 page
PB-501+LS-501+RU-503 . . . . . . . . . . . . . . E-12 page
PB-501+FD-501+RU-503 . . . . . . . . . . . . . . E-14 page
E-1
A075IXE050CB
A075IXE050CC
A075955111

Advertisement

loading

Summary of Contents for Konica Minolta PB-501

  • Page 1 PB-501+1050 Series ..E-4 page • PB-501+SD-501+RU-503 ....E-10 page • PB-501+SD-501 ..E-10 page •...
  • Page 2: Accessory Parts

    (mass: approx. 210 kg) A075IXC004SA [Precaution when transporting the PB-501] 7. Installation When transporting the PB-501 on a slope where plate/5 the pitch changes suddenly (including lifter of a truck and etc.), make sure to transport it back- A075IXC005SA ward or forward.
  • Page 3: Preparation Prior To Installation

    (TP screw M4x6: 2 pcs.) Locking tapes Guide tape A075IXE001SA 4. Open the front door of the PB-501, and remove six Glue injector locking materials (24 screws), the locking tapes and the cushion. Note: There is a plastic sheet under the cushion, so be sure to remove it.
  • Page 4 Installation procedure for materials (7 screws ), raise the Lifter up to the position where it stops, and remove the cushion. [PB-501 + 1050 series] 1. Turn the machine’s Sub and Main power switches OFF, and unplug the power cord.
  • Page 5 4. Install the PB-501 to the machine. (4) Pull out the cover tray, and install the Installa- (1) Connect the three connector jacks of the PB-501 tion plate 4. (TP screw M4x10: 1 pc.) to the connector plugs on the machine.
  • Page 6 11. Perform a software update (ISW). For ISW procedures, see the service manual. Note: The software is designed for the C6500/C6501 series, so be sure to run it. Note: Perform the operations described in "V.Common operations after installing PB-501", page 17 to 19.
  • Page 7 4. Align the bottom hole of the PB-501 with the posi- Installation procedure for tioning pin on the power supply unit, and lock PB-501 + RU-503 (RU-504) + C6500/C6501 series] them by sliding the PB-501 toward the back. For the installation procedure for the RU-503, see the RU-503/504 installation manual.
  • Page 8 Be sure to store the lock shaft for the use when removing the conveyance unit. Lock shaft 15AQIXC008SA 8. Connect the four PB-501 connector jacks to the connector plugs of the RU power supply unit. Note: 15AQIXE053SA RU for C6501/C6501P series is different from the 11.
  • Page 9 12. Loosen two screws, and remove the connector 15. Install the connector cover on the RU convey- cover on the back side of the RU conveyance ance segment (2 screws). Note: segment. Put the wire bundle into the RU machine so that it will not get hooked when the conveyance segment is pulled out.
  • Page 10 3. Remove the connector cover on the left side of the SD-501 (SD-506) (1 screw). 15AQIXF062SA Actuator adjustment plate Loosen the screws to adjust the horizontal position Connector cover Note: 15AEIXE033SA Perform the operations described in "V.Common operations after installing PB-501", page 17 to 19. E-10...
  • Page 11 4. Install the PB-501 to the SD-501 (SD-506). (4) Pull out the cover tray, and install the Installa- tion plate 4. (TP screw M4x10: 1pc.) (1) Connect the four connector jacks of the PB-501 to the connector plugs on the SD-501 (SD-506). SD-501...
  • Page 12 For ISW procedures, see the service manual. (For the 1050 series only) Note: The software is designed for the C6500/C6501 series, so be sure to run it. Note: Perform the operations described in "V.Common operations after installing PB-501", page 17 to 19. Connector cover 15AQIXE034SA E-12...
  • Page 13 4. Install the PB-501 to the LS-501 (LS-505). (4) Pull out the cover tray, and install the Installa- (1) Connect the four connector jacks of the PB-501 tion plate 4. (TP screw M4x10: 1pc.) to the connector plugs on the LS-501 (LS-505).
  • Page 14 For ISW procedures, see the service manual. (For the 1050 series only) Note: The software is designed for the C6500/C6501 series, so be sure to run it. Note: Perform the operations described in "V.Common operations after installing PB-501", page 17 to 19” Connector cover 15AQIXE028SA E-14...
  • Page 15 4. Loosen two screws on the Paper path of the FD-501 7. Install the PB-501 to the FD-501 (FD-503). (FD-503). (1) Connect the four connector jacks of the PB-501 to the connector plugs on the FD-501 (FD-503). FD-501 PB-501 (FD-503)
  • Page 16 For ISW procedures, see the service manual. (For the 1050 series only) Note: The software is designed for the C6500/C6501 series, so be sure to run it. Note: Perform the operations described in "V.Common operations after installing PB-501", page 17 to 19. E-16...
  • Page 17 *Adjustment method Adjust the height of the casters on the PB-501 main unit to correct the slant of the main unit to A075IXE015SA eliminate any interference.
  • Page 18: Serial Number Registration

    * Machine + PB-501 : Finisher 1 VI.Serial Number Registration Machine +other option+ PB-501 Register the serial number of the PB-501 that has : Finisher 2 been installed to the machine. Machine+other optionx2+ PB-501 The location of the serial number is shown in the fig- : Finisher 3 ure below.
  • Page 19: Installation Confirmation

    “Perfect Binder Sub Tray is full Please remove paper.” appears on the control panel. *Adjustment method If the FD full detection does not turn ON, adjust the casters of the PB-501 main unit and raise it to acti- vate the FD full detection. A075IXC015SA E-19...