Acknowledgement Response Return Codes - Advanced - JVC RS-232C Remote Control Manual

D-ila projector
Hide thumbs Also See for RS-232C:
Table of Contents

Advertisement

Acknowledgement Response Return Codes - Advanced

For some functions, it is possible to obtain a more detailed response from the projector. This
is useful where different actions are required depending on the current projector settings or
status. To request the detailed response, taking the above example of the Power Command,
send to the projector:
3F 89 01 50 57 0A
If the projector receives the enquiry command, as a confirmation that it has received the
command, it will first respond with exactly the same information as that returned by the basic
Acknowledgement Return Code shown on page 15:
06 89 01 50 57 0A
Next, the projector will send the detailed response. It will send:
40 89 01 50 57 RR 0A - Where RR is the Detailed Response Return Code.
For clarity, the two returned responses are separated here. In practice, they are returned
from the projector as one continuous string.
For the Power Status Enquiry, the possible values for the Detailed Response Return Code
status (RR) are:
30 - Standby
31 - Power On
32 - Cooling
34 - Emergency
So, as a full worked example, if we send to the projector:
3F 89 01 50 57 0A
If the projector were currently cooling down after being switched to Standby, it would return:
06 89 01 50 57 0A 40 89 01 50 57 32 0A
If the projector were on Standby, it would return:
06 89 01 50 57 0A 40 89 01 50 57 30 0A
A list of all of the useful enquiry codes, together with all possible detailed responses is below:
Power Status (to confirm the current Power Status)
Enquiry Command (to projector)
Response (from projector)
Response (RR)
30
31
32
34
JVC D-ILA Projector Remote Control Guide
06 89 01 50 57 0A 40 89 01 50 57 RR 0A
Page 16 of 25
3F 89 01 50 57 0A
Meaning
Standby
Power On
Cooling
Emergency