IC1 RH-iX0004SJZZ: System Microcomputer (IX0004SJ) (1/2)
Pin No.
Port Name
1
P00/TXD/SBO0
2
P01/RXD/SBI0
3
P02/STB0
4
P03/SBO1
5
P04/SBI1
6
P05/SBT1
7
P06/DK/
BUZZER
8
VDD
9
OSC2
10
OSC1
11
VSS
12
XI
13
XO
14
MMOD
15
VREF-
16-18
PA0/AN0-PA2/AN2 KEY1-KEY3
19
PA3/AN3
20
PA4/AN4
21
PA5/AN5
22
PA6/AN6
23*
PA7/AN7
24
VREF+
25
P07
26
P27/RST
27
P10/TM0IO
28
P11/TM1IO
29
P12/TM2IO
30
P13/TM3IO
31
P14/TM4IO
32
P15
33
P20/IRQ0
34
P21/SEN/IRQ1
35
P22/IRQ2
36
P23/IRQ3
37
P24/IRQ4
38
P25
39
P30/SBO2
40
P31/SBI2
41
P32/SBT2
42
P50
43
P51
44
P52
45
P53
46
P54
47
P67/DGT17
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.

FUNCTION TABLE OF IC

Input/
Terminal
Output
Name
TUN_DI
Output
Data output terminal to the tuner PLL IC
TUN_DO
Input
Data input terminal from the tuner PLL IC
TUNE_CK
Output
Clock output synchronized with the tuner PLL IC
TUN_CE
Output
Enable output for the tuner PLL IC
TUN_MUTE
Output
Tuner mute output terminal
TUN_SD
Input
Terminal for detecting the tuner broadcast reception mode
"L" = During broadcast reception
TUN_ST
Input
Input for detecting whether or not the tuner is receiving stereo radio signals
"H" = MONO, "L" = STEREO
VDD
Microcomputer power supply +5V
OSC2
Output
External oscillator terminel for the main clock
OSC1
Input
External oscillator terminel for the main clock
VSS
Microcomputer power supply GND
XI
Input
External oscillator terminel for the sub clock
XO
Output
External oscillator terminel for the sub clock
MMOD
Input
Memory mode select terminal
VREF-
A/D convertor power supply GND
Input
Operation key input MAX-10 key
AREA
Input
Destination detection input. Operates as an A/D input port
Detects the destination setting on the DC voltage when resetting.
SP_LEVEL
Input
Main speaker output level detection, input
MODEL
Input
Model detection input. Detects the model on DC voltage when resetting.
POSISTOR
Input
Input for detecting an increase in the power amplifier temperature
Not used
VREF+
A/D convertor power supply +5V
ALC
Input
Power output ALC function ON/OFF control terminal
RESET
Input
System reset, input
FS_STB
Output
Function select IC strobe signal
FS_DATA
Output
Function select IC control signal, output
FS_CK
Output
Synchronous clock output to the function select IC
V_LATCH
Output
Latched data output to the electronic volume IC
Model 2000: Electronic volume IC enable, output
V_CK
Output
Synchronous clock for the electronic volume IC
V_DATA
Output
Data output to the electronic volume IC
POWER
Input
Main case primary power switch, input
SYS_STOP
Input
Power failure detection, input. Changes to the STOP mode when "L".
AC3_SO
Input
ZR38600 serial data, input
REMOCON
Input
Remote control signal, input
JOG_UP
Input
Jog dial UP pulse, input
JOG_DOWN
Input
Jog dial DOWN pulse, input
F_MUTE
Output
Front amplifier input, Mute output
R_MUTE
Output
Rear amplifier input, Mute output
C_MUTE
Output
Center amplifier input, Mute output
SW_MUTE
Output
Woofer amplifier input, Mute output "H" = MUTE OFF, "L" = MUTE ON
FA_PLAY
Output
Front 'A' speakers' protective relay control, output
"H" = RLAY CLOSE, "L" = RLAY OPEN
POW_SW
Output
Primary-side AC power ON/OFF relay control, output
HP_MUTE
Headphones signal mute output
R_RLAY
Output
Rear speaker protective relay control, output
"H" = RLAY CLOSE, "L" = RLAY OPEN
C_RLAY
Output
Center speaker protective relay control, output
"H" = RLAY CLOSE, "L" = RLAY OPEN
Function
"L" = OFF, "H" = ON
"H" = MUTE OFF, "L" = MUTE ON
"H" = MUTE OFF, "L" = MUTE ON
"H" = MUTE OFF, "L" = MUTE ON
– 39 –
HT-DD5000W
f = 8.00 MHz
f = 8.00 MHz
f = 32.768 kHz
f = 32.768 kHz
"H" = ON, "L" = OFF
"H" = ON, "L" = OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-f5000wCp-sw5000wCp-sr5000wCp-c5000w

Table of Contents