Re-programming Analog DDC IC
Step 1: After initialize the alignment fixture, connecting
all cables. Be using VGA port from monitor.
Step 2: Connect the power code of monitor and power on it.
Step 3: Double check the
EDID_Tool_3.7 icon to run the
EDID_Tool_3.7.exe.
Step 4: Click the LOAD icon at the main
menu to open the DDC files, load
the files into EDID Tool, The EDID
table will be appeared automatically
as shown in below photos.
Fig 4
Step 5: In the "Detailed Timings", key in the monitor serial
number.
Step 6: Press "Write" button in the tool main ,when the
DDC data download into the monitor, the message will be
appeared automatically as shown in below photos.
Fig 6
190EW9 LCD
Fig 5
17