8. EACH SETTING AND ADJUSTMENT

QQ
3 7 63 1515 0

8.1 CHECKING THE GRATING AFTER CHANGING THE PICKUP UNIT

Note :
The grating angle of the PU unit cannot be adjusted after the PU unit is changed. The PU unit in the CD mechanism
module is adjusted on the production line to match the CD mechanism module and is thus the best adjusted PU
unit for the CD mechanism module. Changing the PU unit is thus best considered as a last resort. However, if the
PU unit must be changed, the grating should be checked using the procedure below.
Purpose :
To check that the grating is within an acceptable range when the PU unit is changed.
Symptoms of Mal-adjustment :
If the grating is off by a large amount symptoms such as being unable to close tracking, being unable to perform
track search operations, or taking a long time for track searching.
Method :
Measuring Equipment
Measuring Points
Disc
Mode
TE
L 13942296513
Checking Procedure
1. In test mode, load the disc and switch the 3 V regulator on.
2. Using the key 08 and key 09, move the PU unit to the innermost track.
3. Press key 03 to close focus, the display should read "91". Press key 02 to implement the
tracking balance adjustment the display should now read "81". Press key 3. The display will change,
returning to "81" on the fourth press.
4. As shown in the diagram above, monitor the LPF outputs using the oscilloscope and check that the phase
difference is within 75 degrees. Refer to the photographs supplied to determine the phase angle.
5. If the phase difference is determined to be greater than 75 degrees try changing the PU unit to see if there is any
improvement. If, after trying this a number of times, the grating angle does not become less than 75 degrees then the
mechanism should be judged to be at fault.
Note
www
Because of eccentricity in the disc and a slight misalignment of the clamping center the grating waveform may be
seen to "wobble" ( the phase difference changes as the disc rotates). The angle specified above indicates the
average angle.
Hint
.
Reloading the disc changes the clamp position and may decrease the "wobble".
5
http://www.xiaoyu163.com
6
Oscilloscope, Two L.P .F .
E, F , REFO1
TCD-782
TEST MODE
CD CORE UNIT(S10.5COMP2)
REFO1
E
F
x
ao
u163
y
i
6
http://www.xiaoyu163.com
7
2 9
8
L.P .F .
Q Q
3
6 7
1 3
1 5
E
100 kohm
390 pF
VREF
F
100 kohm
390 pF
VREF
L.P .F .
co
.
AVIC-F700BT/XS/UC
7
8
9 4
2 8
0 5
8
2 9
9 4
2 8
Xch
Ych
Oscilloscope
m
8
9 9
A
B
C
9 9
D
E
F
75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avic-f7010bt

Table of Contents