Napoleon GD25-N Installation And Operation Instructions Manual

Napoleon GD25-N Installation And Operation Instructions Manual

Listed direct vent millivolt gas-fired wall furnace

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS
W W W W W ARNING:
ARNING:
ARNING:
ARNING: If the information in these instructions is not followed exactly, a fire or
ARNING:
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualified installer, service
Fax: (705)722-6031 Email: ask@napoleon.on.ca
Web: www.napoleon.on.ca
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS,
CSA 2.33, AND ANSI Z21.88 RESPECTIVELY FOR VENTED GAS-FIRED SPACE HEATING APPLIANCES.
LISTED DIRECT VENT MILLIVOL
LISTED DIRECT VENT MILLIVOLT T T T T
LISTED DIRECT VENT MILLIVOL
LISTED DIRECT VENT MILLIVOL
LISTED DIRECT VENT MILLIVOL
GAS-FIRED WALL FURNACE
GAS-FIRED WALL FURNACE
GAS-FIRED WALL FURNACE
GAS-FIRED WALL FURNACE
GAS-FIRED WALL FURNACE
INSTALLA
INST
INST
INST
INST
ALLA
ALLA
ALLATION AND OPERA
ALLA
TION AND OPERA
TION AND OPERATION INSTRUCTIONS FOR:
TION AND OPERA
TION AND OPERA
NATURAL GAS MODEL
PROPANE GAS MODEL
FOR YOUR SAFETY
FOR YOUR SAFETY
FOR YOUR SAFETY
FOR YOUR SAFETY
FOR YOUR SAFETY
this or any other appliance.
WHA
WHAT T T T T T T T T TO DO IF YOU SMELL
WHA
O DO IF YOU SMELL
O DO IF YOU SMELL
WHA
WHA
O DO IF YOU SMELL
O DO IF YOU SMELL GAS:
agency or the gas supplier.
Wolf Steel Ltd., RR#1, 9 Napoleon Rd.,
Barrie, On., Canada L4M 4Y8 (705)721-1212
TION INSTRUCTIONS FOR:
TION INSTRUCTIONS FOR:
TION INSTRUCTIONS FOR:
TION INSTRUCTIONS FOR:
GD25 - N
GD25 - N
GD25 - N
GD25 - N
GD25 - N
GD25 - P
GD25 - P
GD25 - P
GD25 - P
GD25 - P
GAS:
GAS:
GAS:
GAS:
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
R-2000
WS-415-099 / 03.16.99

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GD25-N

  • Page 1 • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Wolf Steel Ltd., RR#1, 9 Napoleon Rd., Barrie, On., Canada L4M 4Y8 (705)721-1212 Fax: (705)722-6031 Email: ask@napoleon.on.ca R-2000 Web: www.napoleon.on.ca...
  • Page 2 After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty.
  • Page 3: Table Of Contents

    PLEASE RET PLEASE RET PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE AIN THIS MANUAL FOR FUTURE REFERENCE AIN THIS MANUAL FOR FUTURE REFERENCE AIN THIS MANUAL FOR FUTURE REFERENCE PLEASE RET PLEASE RET AIN THIS MANUAL FOR FUTURE REFERENCE T T T T T ABLE ABLE ABLE of of of of of CONTENTS ABLE...
  • Page 4: General Information

    Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner.
  • Page 5: Venting

    Use the high temperature sealant provided. When using Napoleon venting components, use only the following vent kits: WALL TERMINAL KIT GD222, or 1/12 TO 7/ 12 PITCH ROOF TERMINAL KIT GD110, 8/12 TO 12/12 ROOF TERMINAL KIT GD111, FLAT ROOF TERMINAL KIT GD112 or PERISCOPE KIT GD201 (for wall penetration below grade) in conjunction with the various terminations, use either the 5 foot vent kit GD220 or the 10 foot vent kit GD330.
  • Page 6 AIR TERMIN TERMIN TERMIN TERMINAL INST AL INST AL INST AL INSTALLA ALLA ALLA ALLATIONS: TIONS: TIONS: TIONS: TERMIN AL INST ALLA TIONS: FIGURE 4 INSTALLATIONS CANADIAN U.S.A. 12 INCHES 12 INCHES Clearance above grade, veranda porch, deck or balcony. 12 INCHES 9 INCHES Clearance to windows or doors that open.
  • Page 7: Wall And Ceiling Protection

    VERTICAL INSTALLATION: This application occurs when venting through FIGURE 6 a roof. FIGURE 3. Installation kits for various roof pitches are available from your Napoleon dealer. See Accessories to order the specific kit required. FIGURE 7 1. Determine the air terminal location, cut and frame 9½ inch openings in the ceiling and the roof to provide the minimum 1 inch clearance between the fireplace pipe / liner and any combustible material.
  • Page 8: Using Flexible Vent Components

    These spacers must not be removed. 2. The vent system must be supported approximately every 3 FIGURE 11 feet for both vertical and horizontal runs. Use Napoleon support ring assemblies, GA-GD-010.370 or equivalent noncombustible strapping to maintain the minimum 1" clearance to combustibles.
  • Page 9 TICAL VENTING INST TICAL VENTING INST ALLA ALLA TION TION VERTICAL VENTING INST TICAL VENTING INST TICAL VENTING INSTALLA ALLA ALLATION TION TION 1. Fasten the roof support to the roof using the screws FIGURE 12 provided. The roof support is optional. In this case the vent- ing is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 10: Using Rigid Vent Components

    HORIZONTAL RUNS MAY HAVE A ZERO INCH RISE PER FOOT The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Napoleon vent spacers WS-615-33 or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes.
  • Page 11 VERTICAL VENTING INST TICAL VENTING INST TICAL VENTING INST TICAL VENTING INST TICAL VENTING INSTALLA ALLA ALLA ALLA ALLATION TION TION TION TION 1. Move the fireplace into position. FIGURE 17 2. Fasten the roof support to the roof using the screws provided. The roof support is optional.
  • Page 12: Gas Installation

    GAS INST GAS INST GAS INST GAS INST GAS INSTALLA ALLA ALLA ALLATION ALLA TION TION TION TION Proceed once the vent installation is complete. 1. Move the fireplace into position. 2. Route a 3/8" N.P.T. black iron gas line, 1/2" type-L copper tubing or equivalent to the fireplace. 3.
  • Page 13: Framing

    FRAMING FRAMING FRAMING FRAMING FRAMING It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. FIGURE 23-26. FIGURE 25 OUTSIDE CHASE INSIDE CHASE FIGURE 24 FIGURE 26 FIGURE 23 To install the fireplace face flush with the finished wall, position the framework to accomodate the thickness of the...
  • Page 14: Finishing

    LOG PLACEMENT PHAZER logs and glowing embers (available as an option from your Napoleon dealer), exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glow- FIGURE 28 ing embers for a maximum glowing effect.
  • Page 15: Door Removal & Installation

    Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZER logs glow when exposed to direct flame. Use only certified "glowing embers" and PHAZER logs available from your Napoleon / Wolf Steel Ltd. dealer. STEEL LIP DOOR, LOUVRE AND TRIM REMOV DOOR, LOUVRE AND TRIM REMOV AL &...
  • Page 16: Optional Blower Installa

    OPTIONAL BLOWER INSTALLATION INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE Canada or the ANSI/NFPA 70-1996 in the United States NATIONAL ELECTRICAL CODE If the fireplace was not previously equipped with a blower: route a...
  • Page 17: Optional Fan Installation

    THERMODISC This optional kit is meant to be used only in conjunction with the GD65 Fan SENSOR ASSEMBLY Kit, shown above, which may be ordered from your Wolf Steel / Napoleon BRACKET dealer. With the thermostatic sensor option, the fan, when turned on, becomes...
  • Page 18: Maintenance

    6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer / distributor.
  • Page 19: Adjustments

    ADJUSTMENTS FIGURE 43 THERMOPILE PILOT BURNER THERMO- COUPLE ELECTRODE PILOT BURNER ADJUSTMENT PILOT BURNER ADJUSTMENT PILOT BURNER ADJUSTMENT PILOT BURNER ADJUSTMENT PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized PILOT SCREW FIGURE 42 flame. Turn in a clockwise direction to reduce the gas flow.
  • Page 20: Vent Kits

    ARTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1. Model & Serial Number of fireplace 3.
  • Page 21: Terminal Kits

    TERMINAL KITS TERMINAL KITS TERMINAL KITS TERMINAL KITS TERMINAL KITS ROOF TERMINAL KITS: ROOF TERMINAL KITS: 1/12 TO 7/12 PITCH ROOF TERMINAL KITS: 1/12 TO 7/12 PITCH 1/12 TO 7/12 PITCH 1/12 TO 7/12 PITCH - - - - - GD110 GD110 GD110...
  • Page 22: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM SYMPTOM SYMPTOM PROBLEM PROBLEM PROBLEM TEST SOLUTION TEST SOLUTION TEST SOLUTION SYMPTOM SYMPTOM PROBLEM PROBLEM TEST SOLUTION TEST SOLUTION Main burner flame...
  • Page 23 SYMPTOM SYMPTOM SYMPTOM PROBLEM PROBLEM PROBLEM SYMPTOM SYMPTOM PROBLEM PROBLEM TEST SOLUTION TEST SOLUTION TEST SOLUTION TEST SOLUTION TEST SOLUTION Pilot will not light. No spark at pilot burner - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor. - check if the push button ignitor needs tightening.
  • Page 24 NOTES: WS-415-099 /03.16.99...

This manual is also suitable for:

Gd25-p

Table of Contents